Instruction Manual
For Model MH2065v
Fan Cooled Strobe Head
Replacement of Modeling Lamp
1. Unplug the flash head
from the power pack 
and allow the flash 
head to cool before 
touching the modeling 
lamp. 
2. Remove flash head
accessories if present.
3. Remove the flash tube from the head in or-
der to reach the modeling lamp.
4. Remove the modeling lamp by carefully
griping it with a soft cloth and pulling 
straight out. 
5. Install the new lamp by aligning the pins
with the socket and press the lamp in place.
Please note: Do not touch the new lamp with your hands. 
Oils from your hands can cause premature failure of the 
lamp or could cause an unexpected shattering of the lamp. 
 
Replacement of the Flash Tube
1. Unplug the flash head
from the power pack 
and allow the flash head 
to cool before touching 
the flash tube. 
2. Remove flash head ac-
cessories if present.
3. Remove the flash tube by rocking and or
pulling the outer edge of the reflector as-
sembly out of the flash housing. 
4. Install the new flash tube assembly by align-
ing the three connection pins with the three 
connection sockets inside the flash housing. 
Ensure that the connection pins are aligned 
correctly and in the proper configuration 
before installing the flash tube assembly. 
Gentle push the reflector/flash tube assem-
bly until the edge of the reflector is flush 
with the outer edge of the flash housing. 
Note: Use only the appropriate flash tube.