Brocade Communications Systems Brocade Netiron XMR 32000 User Manual
Page 7

Packet Over SONET/SDH
• RFC 1661 The Point-to-Point Protocol (PPP)
• RFC 1662 PPP in HDLC-like Framing
• RFC 2615 PPP over SONET/SDH
• RFC 1332 Internet Protocol Control Protocol (IPCP)
• RFC 1377 The PPP OSI Network Layer Control Protocol (OSINLCP)
• RFC 2472 IPv6 over PPP
• RFC 3592 SONET/SDH Objects
• GR-253-CORE SONET Transport Systems: Common Generic Criteria
• G.707/Y.1322 Network Node Interface for SDH
MEF Certification
• MEF 9 Certified—Abstract Test Suite for Ethernet Services at the UNI
• MEF 14 Certified—Abstract Test Suite for Traffic Management Phase 1
Network Management
• IronView Network Manager (INM) Web-based graphical user interface
• Integrated industry standard Command Line Interface (CLI)
• sFlow (RFC 3176)
• Telnet
• SNMP v1, v2c, v3
• SNMP MIB II
• RMON
Element Security Options
• AAA
• RADIUS
• Secure Shell (SSH v2)
• Secure Copy (SCP v2)
• HTTPs
• TACACS/TACACS+
• Username/Password (Challenge and Response)
• Bi-level Access Mode (Standard and EXEC Level)
• Protection against Denial of Service attacks, such as TCP SYN or Smurf Attacks
Environmental
• Operating Temperature: 0° C to 40° C (32° F to 104° F)
• Relative Humidity: 5% to 90%, @40° C (104° F), non-condensing
• Operating Altitude: 6,600 ft (2,012 m)
• Storage Temperature: -25º C to 70º C (-13º F to 158° F)
• Storage Humidity: 95% maximum relative humidity, non-condensing
• Storage Altitude: 15,000 ft (4,500 m) maximum
Safety Agency Approvals
• CAN/CSA-C22.2 No. 60950-1-3
• UL 60950-1
• IEC 60950-1
• EN 60950-1 Safety of Information Technology Equipment
• EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification,
Requirements and User’s Guide
• EN 60825-2 Safety of Laser Product—Part 2: Safety of Optical Fibre
Communication Systems
Electromagnetic Emission
• ICES-003 Electromagnetic Emission
• FCC Class A
• EN 55022/CISPR-22 Class A/VCCI Class A
• AS/NZS 55022
• EN 61000-3-2 Power Line Harmonics
• EN 61000-3-3 Voltage Fluctuation & Flicker
• EN 61000-6-3 Emission Standard (Supersedes: EN 50081-1)
Immunity
• EN 61000-6-1 Generic Immunity and Susceptibility. Supersedes: EN 50082-1
• EN 55024 Immunity Characteristics. Supersedes:
— EN 61000-4-2 ESD
— EN 61000-4-3 Radiated, radio frequency, electromagnetic field
— EN 61000-4-4 Electrical fast transient
— EN 61000-4-5 Surge
— EN 61000-4-6 Conducted disturbances induced by radio-frequency fields
— EN 61000-4-8 Power frequency magnetic field
— EN 61000-4-11 Voltage dips and sags
TELCO NEBS/ETSI
Designed to meet the following specifications (formal testing under way):
• Telcordia GR-63-CORE NEBS Requirements: Physical Protection
• Telcordia GR-1089-CORE EMC and Electrical Safety
• Telcordia SR-3580 Level 3
• ETSI ETS 300-019 Physical Protection
- Part 1-1, Class 1.1, Partly Temperature Controlled Storage Locations
- Part 1-2, Class 2.3, Public Transportation
- Part 1-3, Class 3.1, Temperature Controlled Locations (Operational)
• ETSI ETS 300-386 EMI/EMC
Power and Grounding
• ETS 300 132-1 Equipment Requirements for AC Power Equipment Derived
from DC Sources
• ETS 300 132-2 Equipment Requirements for DC Powered Equipment
• ETS 300 253 Facility Requirements
Physical Design and Mounting
19-inch rack mount
supporting racks
compliant with:
• ANSI/EIA-310-D
• ETS 300 119
• GR-63-CORE Seismic Zone 4
Tabletop
Environmental Regulatory Compliance
• EU 2002/95/EC RoHS (with lead exemption)
• EU 2002/96/EC WEEE