beautypg.com

Clay Paky WATER COLUMN User Manual

Page 2

background image

4

POSSIBLE CAUSES

CHECKSAND REMEDIES

No mains power supply.

Check that the power supply
connector is receiving power, and/or
that the fuses have not blown.

Transformer has failed.

Contact an authorised technician.

Lamp burnt out.

Replace the lamp.

PROBLEMS

THE LAMP DOES NOT COME ON

NO OR TOO FEW BUBBLES

COLOUR DISC DOES NOT TURN

Compressor has failed.

Contact an authorised technician.


Porous element dirty.

Contact an authorised technician..

Motor has failed.

Contact an authorised technician.

Dust or grease deposits.

Clean (see instructions).

LIGHT TOO DIM

TROUBLESHOOTING

4

MAINTENANCE

3

• Changing the lamp

Undo the wing-nuts (

8) and open the lid

(7) giving access to the lamp compart-
ment. Remove the faulty lamp (9) from
the socket (

10), then take the new lamp

from its pack. Read the "instructions for
use" provided by the lamp manufacturer
carefully, and fit it into the socket (

10),

checking that the tabs are properly posi-
tioned. Replace the lid (7) and tighten the
wing-nuts (8).

• Changing the fuses

Extract the fuse-box (11), taking hold of it
by the side tangs. Replace the blown
fuses with new fuses of the type stated on
the label (12) on the fuse-box (11) and put
the box back in place.

• Routine cleaning

To maintain optimum performance and
efficiency over the long-term, the parts
where dust and grease accumulate must
be cleaned periodically. To remove dirt
from the protective glass (13) of the lamp
and colour filters (14), use a soft cloth
dipped in any window-cleaning liquid.

The inside surface of the cylinder should be cleaned every year, emptying out the
water it contains.

Clean the outside and inside of the cylinder using water with neutral soap only.
Dry with a soft (non abrasive) cloth.

7

8

9

10

12

11

14

13

TECHNICAL DATA

5

Power supply
100-120V 60Hz
200-240V 50Hz
The projector is designed to work at
the frequency and voltage given on
the electrical data label on the back of
the appliance.

Lamp
Halogen dichroic lamp.

- Voltage: 12V.
- Power: 50W.
- Nominal lifetime: 4,000 hours.
- Colour temperature: 3,100 K.
- Cap: GU5,3.

Colour disc
Continuously rotating colour disc
1 rev/min, 8 colours: red, blue,
orange, violet, green, pink, yellow
and white.
The colour filters on the wheel can
easily be replaced with other filters in
polycarbonate or dichroic glass

Bubbles
Bubble generation cycle (interval

between bursts): 3 seconds.

Duration of burst: 4.5 seconds.

Maximum power absorption
110VA.

Safety devices
2 line fuses.
Degree of protection IP20.
Conforms to EC directives.

Body
ABS base.
Clear plastic (PMMA) cylinder.

1

9

7

5

7

7

,7

6

ш150

ш5,91”

2

8

5

1

1

,2

2

356

14,02”

356

14,02”

Operating position
Operates in vertical position.

Weight, capacity and dimensions
Weight: 12 Kg (empty)

(26 lbs 6 ozs).

Capacity: about 30 litres.

After all the operations described above have been carried out, supply power to the
device and check that the lamp lights up, and that bubble production and the rotation
of the colour disc begin.

L

N

Power supply

2

• Connecting to the mains power supply

The device must be connected to the electricity supply system by means of the
connector (

2) provided.

Each device should be connected by means of a switch of its own, so that it can be
switched on and off separately from a distance.