TECHNICAL DATA
6
Power supplies available
• 220 - 240V 50Hz
• 200V 50Hz - 230V 60Hz
• 200 - 220V 60Hz
• 260V 50Hz
• 120V 60Hz
• 100V 50Hz
• 100V 60Hz
The projector is designed to work at the
frequency and voltage given on the
electrical data label on the back of the
appliance.
Input power
• 200VA at 230V 50Hz
(standard power factor correction 20µF)
Lamp
Metal halide supplied with special built-in
power supply unit.
• Type HQI-T 150/NDL PRO
- Connection G12
- Colour temperature 4,200 K
- Luminous flux 13,000 lm
- Average life 9,000 h
- Any working position (recommended
p45).
Optical unit
• Base in die-cast aluminium.
• Twin lens condenser.
• Spherical reflector with a high
luminous efficiency.
Lens units
• Standard: 1:2,4/100 mm (30,9°)
• Optional: 1:2,8/45 mm multi-lens (64,2°)
• Optional: 1:2,8/60 mm multi-lens (45,8°)
• Optional: 1:2,8/85 mm multi-lens (34,4°)
• Optional: 1:2,8/120 mm multi-lens (24,1°)
• Optional: 1:3,5/150 mm multi-lens (19,5°)
• Optional: 1:4/165 mm (17,2°)
• Optional: 1:4,4/200 mm (14,3°)
• Optional: 1:3,5/70÷120 mm zoom
(39,5°÷22,9°)
Safety Devices
• Power supply automatically cut off in
the event of overheating.
• Shor t-circuiting protection on the
accessory holder guides.
Cooling
Forced ventilation with an axial fan.
Body
• In die-cast and extruded aluminium.
• Epoxy powder painting.
Mounting
• Bracket in steel painted with epoxy
powders.
• Three installation positions with a step
of 25 mm (0.98”).
• Bracket adjustable on 120°.
Working position
Operation in any position limited to the
lamp characteristics.
Weights and dimensions
Versions 200-240V: 5,8 kg (12 Ibs 12 ozs).
Versions 100-120V: 9,1 kg (20 Ibs).
A
At
(6.69”)
170
(8.07”)
205
(5.12”)
130
(8.86”) 225
(10.83”) 275
TROUBLESHOOTING
5
No mains supply.
Check the supply socket is
powered and/or fuse
conductivity.
THE PROJECTOR WILL NOT SWITCH ON
NO MOTOR-DRIVEN ACCESSORY WORKS
TROUBLE
DEFECTIVE PROJECTION
REDUCED BRIGHTNESS
POSSIBLE CAUSES
CHECKS AND REMEDIES
•
•
•
•
•
•
•
•
Lamp exhausted or defective.
Replace the lamp.
(See instructions).
No power on the guides.
Call an authorized technician.
The accessory motors fail to
work.
Call an authorized technician.
Lenses or reflector broken.
Call an authorized technician.
Dust or grease deposited.