3

5

17

5

17

• Installing the projector

The projector can be installed on the ceiling or on a wall through the holes in the
bracket. It is recommended to use 2 screws ø12mm with nut and spring washer.

CAUTION: Check the plates (3 and 4) are correctly secured to the sides of the
fitting; If the plates has been removed, to carry out non-routine maintenance
work, reposition them, following the relevant instructions and checking the
threads in the projector sides hold properly.

• Securing the safety ropes

Except for when the projector is standing on the floor, it is compulsory to fit the
safety rope (17).
These need to be secured to the projector framework and then
hooked onto the eyebolts (5) screwed into the sides of the projector

INSTALLATION AND FINE-TUNING

3

• Adjusting the projector position

180

°

50

°

50

°

7

9

GOLDEN SCAN HPE

• Mains power connection

It is advisable to connect each projector via its own switch so as to be able to switch
it on and off individually from a distance.

N

L

1 0

1 0

1 0

23

25

26

24

Mains

BROWN

=

BLUE

=

YELLOW

=

GREEN

=

L

N

=

• Selection of voltage/frequency

Open up the effects compartment
of the projector by lifting the
relative cover (see heading
8 MAINTENANCE) and locate the
voltage change terminal (23)
mounted to the effects assembly
frame (24). Use a screwdriver to
disconnect the cable (25) from the
terminal it occupies, and reconnect
to the terminal alongside, referring
to the label (26) alongside the
terminal. Having completed the
operation, refit the cover.

• Connecting the control signals

0-10V CONNECTION

0 - 10V

0 - 10V

0 - 10V

1 0

1 0

1 0

Is

1 IRIS

5 PAN

3
COL (2)

DIM 4
STOP

COL (1)

2

6

TILT

7 FROST

FOCUS +

9

PRISM

8

Is

11 ROT.

ROTATE

12

GOBO

FIXED 10

GOBO

EFFECT

ANGLE

GOBO

The connection between controller and projector must be made using a multifcore
cable with 8 wires of 0,25mm

2

section and a DIN 8 PIN 45° plug/socket connector

.