Brown = blue = yellow = green, Installation and fine-tuning – Clay Paky GOLDEN SCAN HPE (HMI 1200) User Manual
Page 3
3
5
17
5
17
• Installing the projector
The projector can be installed on the ceiling or on a wall through the holes in the
bracket. It is recommended to use 2 screws ø12mm with nut and spring washer.
CAUTION: Check the plates (3 and 4) are correctly secured to the sides of the
fitting; If the plates has been removed, to carry out non-routine maintenance
work, reposition them, following the relevant instructions and checking the
threads in the projector sides hold properly.
• Securing the safety ropes
Except for when the projector is standing on the floor, it is compulsory to fit the
safety rope (17). These need to be secured to the projector framework and then
hooked onto the eyebolts (5) screwed into the sides of the projector
INSTALLATION AND FINE-TUNING
3
• Adjusting the projector position
180
°
50
°
50
°
7
9
GOLDEN SCAN HPE
• Mains power connection
It is advisable to connect each projector via its own switch so as to be able to switch
it on and off individually from a distance.
N
L
1 0
1 0
1 0
23
25
26
24
Mains
BROWN
=
BLUE
=
YELLOW
=
GREEN
=
L
N
=
• Selection of voltage/frequency
Open up the effects compartment
of the projector by lifting the
relative cover (see heading
8 MAINTENANCE) and locate the
voltage change terminal (23)
mounted to the effects assembly
frame (24). Use a screwdriver to
disconnect the cable (25) from the
terminal it occupies, and reconnect
to the terminal alongside, referring
to the label (26) alongside the
terminal. Having completed the
operation, refit the cover.
• Connecting the control signals
0-10V CONNECTION
0 - 10V
0 - 10V
0 - 10V
1 0
1 0
1 0
Is
1 IRIS
5 PAN
3
COL (2)
DIM 4
STOP
COL (1)
2
6
TILT
7 FROST
FOCUS +
9
PRISM
8
Is
11 ROT.
ROTATE
12
GOBO
FIXED 10
GOBO
EFFECT
ANGLE
GOBO
The connection between controller and projector must be made using a multifcore
cable with 8 wires of 0,25mm
2
section and a DIN 8 PIN 45° plug/socket connector
.