Information menu – Clay Paky ALPHA BEAM 700 (C61360) User Manual
Page 11
11
ALPHA BEAM 700
SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since
the fixtures switching-on.
1) Pressing
F
you are allowed to reset the SYSTEM ERRORS list.
A confirmation message (Are you sure you want to clear error list ?)
appears on the display.
2) Select YES to reset the list or NO to go back.
FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working life hours (from manufacture to
date).
Partial counter
Counts the number of partial projector working life hours since the
last reset to date.
2) Press
F
to reset partial projector working hours a confirmation
message (Are you sure?) appears on the display.
3) Select YES to reset partial projectors counter or NO to keep the
current setting and return to the top menu level.
LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working hours with the lamp on (from
manufacture to date).
Partial counter
Counts the number of lamp working hours since the last reset to date.
2) Press
F
to reset partial lamp working hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
LAMP STRIKES
Used for displaying the number of times the lamp was turned on (total and
partial).
1) Press
F
- the number of times the lamp was turned on (total and
partial) appears on the display.
Total counter
Counts the number of times the lamp was turned on (from manufacture
to date).
Partial counter
Counts the number of times the lamp was turned on since the last
reset to date.
2) Select YES to confirm the selction or NO to keep current setting.
OPTION
DEFAULT
Lamp DMX
On
Invert Pan
Off
Invert Tilt
Off
Swap Pan-Tilt
Off
Encoder Pan-Tilt
On
Color mixing
CMY
Color mixing curve
Curve 1
Fixed Wheel Shortcut
On
Shutter on error
Off
Dimmer on Shutter
Off
Power Mode
4-700 Full fan speed
Display
On
Lamp
Strikes
Total
XXX
Partial XXX
Reset...
Continue
➔
Lamp
Hours
Total
XXX
Partial XXX
Reset...
INFORMATION MENU
Information
System
Errors
Fixture
Hours
Total
XXX
Partial XXX
Reset...