Default Settings
The default settings for the DigiRoller
™
Plus II
are:
■
Feet-Inch Mode
■
One Meter Wheel
■
100% Wheel Calibration*
■
Display Contrast Level 4
■
Bell On
*On the DigiRoller
™
Plus II
, you can reset the unit by pressing [Set] then
press the [Light] key four times. This will display:
Press [Reset] to clear the display and begin measuring.
Changing the Calibration Percentage
You can change the wheel calibration percentage to be less than or
greater than 100%, to add or subtract a percentage factor to your mea-
surements. To change the calibration percentage:
1. Press the [Set] then [Light] keys.
2. Press the [Set] key to scroll to preference 4, calibration setting.
3. Use the [M+] and [M-] keys to move the percentage up or down.
Press [Set].
4. Press the [RESET] key to exit.
6425-UG-C 4/4/03 12:44 PM Page 43