Copyright (c) 2011 Blizzard Lighting, LLC

3. SETUP

Fuse Replacement

CAUTION! The ROCKLITE™ TRI utilizes a high-output switch-mode

power supply with an internal fuse. Under normal operating condi-

tions, the fuse should not require replacement. The fuse is fi eld

replaceable, however it is an advanced procedure suited to qualifi ed

individuals. Should your ROCKLITE™ fuse require replacement, please

contact Blizzard Lighting for instructions, or to return your unit for

service.

Connecting A Bunch of ROCKLITE™ TRI Fixtures
You will need a serial data link to run light shows using a DMX-512

controller or to run shows on two or more fi xtures set to sync in mas-

ter/slave operating mode. The combined number of channels required

by all the fi xtures on a serial data link determines the number of fi x-

tures the data link can support.

Fixtures on a serial data link must be daisy chained in one single line.

Also, connecting more than 32 fi xtures on one serial data link without

the use of a DMX optically-isolated splitter may result in deterioration

of the digital DMX signal.

The maximum recommended cable-run distance is 500 meters (1640

ft). The maximum recommended number of fi xtures on a serial data

link is 32 fi xtures.

Data/DMX Cabling
To link fi xtures together you’ll need data cables. You should use data-

grade cables that can carry a high quality signal and are less prone to

electromagnetic interference.

For instance, Belden© 9841 meets the specifi cations for EIA RS-485

applications. Standard microphone cables will “probably” be OK, but

note that they cannot transmit DMX data as reliably over long distanc-

es. In any event, the cable should have the following characteristics:

2-conductor twisted pair plus a shield

Maximum capacitance between conductors – 30 pF/ft.

Maximum capacitance between conductor & shield – 55 pF/ft.

Maximum resistance of 20 ohms / 1000 ft.

Nominal impedance 100 – 140 ohms