beautypg.com

Page 15 – Blizzard Lighting 500 HushPar Infiniwhite User Manual

Page 15

background image

Page 15

HushPar Infiniwhite Manual Rev. A

© 2014 Blizzard Lighting, LLC

DMX Values In-Depth (3-Channel ACW Mode)

ch. Value

What it Does (3 ch.)

1

000 <--> 255

Amber Intensity (0% <--> 100%)

2

000 <--> 255

Warm White Intensity (0% <--> 100%)

3

000 <--> 255

Cool White Intensity (0% <--> 100%)

troubleshooting

Symptom

Solution

Fixture Auto-Shut

Off

Check the fan in the fixture. If it is stopped or

moving slower than normal, the unit may have

shut itself off due to high heat. This is to pro-

tect the fixture from overheating. Clear the fan

of obstructions, or return the unit for service.

Beam is Dim

Check optical system and clean excess dust/

grime. Also ensure that the 220V/110V switch

is in the correct position, if applicable.

No Light Output

Check to ensure fixture is operating under cor-

rect mode, IE sound active/auto/DMX/Etc., if

applicable.

Chase Speed Too

Fast/Slow

Check to ensure proper setup of speed adjust-

ment.

No Power

Check fuse, AC cord and circuit for malfunction.

Blown Fuse

Check AC cord and circuit for damage, verify

that moving parts are not restricted and that

unit’s ventilation is not obstructed

Slow Movement

Verify that 220V/110V switch is in the correct

position, if applicable. Also check that speed

channels are set appropriately.

No Response to

Audio

Verify that the fixture is in “Sound Active” mode.

Adjust Audio Sensitivity, If Applicable.

Fixture Not

Responding /

Responding

Erraticly

Make sure all connectors are seated properly

and securely.

Use Only DMX Cables and/or check cables for

defects

Install a Terminator.

Reset fixture(s).

Fixture Moving On

Its Own

Verify proper mode of operation. Is the fixture

in “Auto” mode?

if your problem persists or isn’t listed contact [email protected].