SERVICE (cont.)

TRANSFORMER

FIG. 8 TRANSFORMER

Location:

The transformer(s) is located in the stand housing

on the base plate.

Test Procedures:

1. Disconnect the stand from the power source.

2. Disconnect the black wire from terminal #5 and

the white or red wire from terminal # 6.

3. Check the voltage across the black and white or

red wire with a voltmeter. Connect the stand to

the power supply. The indication must be:

a.) 120 volts ac for two wire 120 volt models.

b.) 200 to 240 volts ac for two wire 200 or 240

volt models.

4. Disconnect the stand from the power supply.

If voltage is present as described reconnect the wires

and proceed to #5.

If voltage is not present as described, refer to the wiring

diagrams and check the stand wiring harness.