57 – Outer barrier is not up and latched and

ground detect switch did not deactivate (Century
and Vista only)

58 – Outer barrier is not up and latched and the plat-

form is 3” above the ground

59 – Outer barrier is not up after pausing platform

travel

60 – The kickout gas springs are worn, replace before

using

75 – Low voltage detected; must turn off power switch

to reset LCD

77 – Vehicle secure interlock has not been activated
90 – Position will be set if you keep holding the button

until it beeps

91 – Position is out of a predetermined acceptable

range of floor position

92 – Bridge switch is not made, needs adjusting
93 – Inner rollstop occupied switch is not made,

position needs to be moved or switch should be
adjusted

94 – Outer barrier is not made, fix and try again
95 – Outer barrier latch is not made (check for jumper

on Century and Vista lifts, check latch on Millen-
nium lifts)

99 – Controller program is not valid; replace controller

Flashing

Numbers

Flashing 65 – Unfold button is pressed
Flashing 66 – Fold button is pressed
Flashing 67 – Down button is pressed
Flashing 68 – Up button is pressed
Flashing 69 – Bridge switch is activated
Flashing 70 – Outer barrier latch switch is activated
Flashing 71 – Ground detect switch is activated
Flashing 72 – Outer barrier up switch is activated
Flashing 73 – Inner rollstop up switch is activated
Flashing 74 – Inner rollstop occupied switch is acti-

vated

Flashing 76 – Outboard barrier occupied switch is
activated
Flashing 78 – Threshold tape switch “A” is activated
Flashing 79 – Threshold tape switch “B” is activated
Flashing 80 – Position set button is pressed

LCD Lift Codes

Listed below are codes that the lift controller outputs
during lift operation. The codes will be displayed
on an LCD screen located on the lift control board
inside the pump module. See the Manual Operating
Instructions in the operator's manual for pump cover
removal instructions.

Non-Flashing Numbers

01 – Platform stowed
02 – Platform unfolding
03 – Platform unfolding paused
04 – Platform at floor level
05 – Platform beginning to lower
06 – Platform lowering (threshold cannot be occu-

pied from this point down)

07 – Outer barrier moving to horizontal position
08 – Platform at ground level
09 – Outer barrier moving to vertical position
10 – Platform raising
11 – Platform raising paused at floor
12 – Platform folding (limited pressure)
13 – Platform folding (full pressure)
14 – Timed fold (cinching lift tite) or (anti-rattle state)
15 – Platform folding stopped
16 – Paused fold
17 – Platform between ground and 3” above ground
18 – Platform above 3”
19 – Outer barrier moving to horizontal postion
23 Outer barrier going back down after occupant

detected

28 – Illegal function/not defined
29 – Interlock fault not recognized (or has been

cleared but a motion button is still pressed)

30 – Platform location unknown
31 – Platform location transition state; attempting to

locate position

35 – Two or more motion buttons are being pressed
36 – The retention belt cannot be buckled while try-

ing to fold or unfold

37 – Motion button being pressed is not a valid mo-

tion

50 – Outer barrier is not up above inboard barrier

locked position

51 – Threshold is occupied when platform is 1” or

more below floor level

52 – Inner rollstop is not up and locked below inner

rollstop locked position

53 – Inner rollstop occupied sensor is not activated

between floor and inner rollstop up position

54 – Outer barrier is occupied before it is up
55 – Outer barrier is not latched when above the in-

ner rollstop locked position (Millennium only)

56 – Outer barrier is not up and latched and bridge