SECTION III

PRE-FAB INSERT INSTALLATION

The Model 85 may be installed into any UL listed pre-fabricated fireplace that is large enough
to accept it
NOTE: The ash lip, smoke baffle, and smoke shelf of the pre-fab fireplace may be removed if

necessary to provide room for these models. Any other alteration to the unit will void ALL
NBC manufacturer's responsibility, liability. The warning label below must be attached to the
back of the fireplace.

NOTE: Plug the power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to
“High” position to ensure motor operates properly. Route the cord to prevent damage to the
cord insulation from heat and sharp objects. Keep the cord out of the way of traffic to prevent
damage caused by tripping, etc.


NOTE: DO NOT BLOCK ANY EXISTING LOUVERS OR VENTS ON THE EXISTING
PRE-FAB WITH ANY TRIM PANELS FOR THE MODEL 85.

Except for the “NOTES” above, please follow the instruction of masonry installation,
Section II.

Instruction
Minimum clearances for stove
Minimum clearances for floor protector







WARNING:

This fireplace must be

restored to its original condition for safe use
if the fireplace insert is removed.

NOTE:

When installing the Model 85 into a Pre - Fab Zero - Clearance fireplace, a

UL-1777 LINER must be installed the Full Length of the chimney and attached to the
flue exit of the insert.

12