beautypg.com

Wood’s Powr-Grip V1275 User Manual

Valve grinder

background image

Based on product information at time of printing.

Valve Grinder

Rev. 0.0 / 02-06

P.O. Box 368 - 908 West Main

1-800-548-7341

Fax: 1-406-628-8354

Laurel, MT 59044

1-406-628-8231

www.powrgrip.com

U.S.A.

Sold through authorized dealers

Products are manufactured under
an ISO 9001 quality management system

INSTRUCTIONS

V1275

Weight: 4 oz [110 g]

Intended Use: Pick up and position clean, relatively smooth, nonporous materials, at temperatures from 0° to 120° F [-18°
to 49° C]. See Vacuum Pads for capacities.

Cautions: Moisture or contaminants can reduce the slip resistance of vacuum pads. Test for staining or deformation of
surfaces with light colors or soft coatings.

Operation: To attach, depress the pump plunger while pressing the vacuum pad onto the valve. Then release the plunger.
Note: When the pad is attached correctly, the plunger should remain partially hidden within the handle; if not, make sure the
pad face and valve face are clean.

To release, set down the material and depress the plunger until the pad comes free.

Note: For quick pick-and-place operations, use a partial pump stroke to attach and a full stroke to release the material.

Vacuum Pads: Interchangeable pads are available to fit most standard valves.

Model No.

Pad Dia.

Max. Capacity

VG0750

3/4" [20 mm]

16 oz [455 g]

VG1000

1" [26 mm]

29 oz [824 g]

VG1250

1-1/4" [32 mm]

46 oz [1307 g]

Maintenance: Keep clean. Store in original pouch when not in use. Replace vacuum pads when worn or damaged.

The ULTIMATE vacuum stick for lapping 4-cycle valves.

Pump provides long-lasting hold. Plunger serves as a
leakage indicator, to help prevent unexpected release.