Elease the, Ads from the – Wood’s Powr-Grip VL411LDC User Manual
Page 13

Rev 17.0/12-12
11
VL411LDC: #35162
In Case of Power Failure
The lifter is equipped with a vacuum reserve tank, designed to maintain vacuum temporarily in
case of a failure at the lifter's power source.
WARNING: Stay clear of any suspended load in the event of a power failure.
Although the lifter is designed to support the load for at least 5 minutes without power, this
depends on many factors, including the condition of the load and the lifter’s vacuum system (see
INTENDED USE: L
OAD
C
HARACTERISTICS
and MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
,
V
ACUUM
T
EST
). If a power failure occurs, keep all personnel clear of the suspended load until it can
safely be placed on the ground or a stable support. Correct any deficiency before resuming
normal operation of the lifter.
T
O
R
ELEASE THE
P
ADS FROM THE
L
OAD
WARNING: Load must be fully supported before releasing vacuum pads.
When the load is at rest and fully supported, pinch the
valve release lever against the valve handle, and push
the valve handle inward to the “RELEASE” position
(power off) until the vacuum pads disengage
completely from the load.
TO RELEASE