3
FLEXR-HV11AC: #35035
SPECIFICATIONS
Description:
Designed for use with a crane or other hoisting equipment, the FLEXR-HV11AC
lifters employ vacuum to hold a load for lifting in the flat orientation.
Model Number:
FLEXR4HV11AC (w/4 Vacuum Pads)
FLEXR6HV11AC (w/6 Vacuum Pads)
Load Capacity:
(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
1
)
Per-Pad:
300 lbs [136 kg]
300 lbs [136 kg]
Maximum:
1200 lbs [545 kg]
1500 lbs [680 kg]
Lifter Weight:
135 lbs [62 kg]
146 lbs [67 kg]
Power Source:
See serial number plate for specific AC voltage, frequency and amperage.
Vacuum Pads:
2
10" [25 cm] nominal diameter, lipped (Model HV11), standard rubber, spring-
mounted (¾" [20 mm] travel), with #60 filter screen
Pad Spread:
(to outer edges)
Maximum:
41" x 70¼" [1041 x 1784 mm]
Minimum:
23" x 54¼" [584 x 1378 mm]
Vacuum Pump:
Rotary vane type, 4 SCFM [113 liters/minute] nominal airflow
or
Diaphragm type, 3 SCFM [85 liters/minute] nominal airflow
Vacuum Reserve Tank: Vacuum reservoir helps prevent immediate vacuum loss in case of power failure.
Vacuum Gauge:
Dial gauge indicates current vacuum level in positive inches of Hg and negative kPa.
Vacuum Lift Light:
Green light is energized whenever vacuum level is sufficient for lifting maximum
load weight (higher than 16" Hg [-54 kPa]).
Options:
See separate instructions about optional features.
Operating Elevation:
Maximum = 10,000 feet [3048 meters]
Operating Temperatures: 32° to 100° F [0° to 38° C]
Service Life:
This lifter is designed to have a service life of at least 20,000 lifting cycles, when
used and maintained as intended. Vacuum pads, filter elements and other wear-out
items are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more
information. For the D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED
USE.
ASME Standard BTH-1: Design Category "B", Service Class "0" (see www.powrgrip.com for more
information)
!!-CE-!! Note: This symbol appears in the
INSTRUCTIONS
manual only when requirements of a CE Standard are
different
from requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory
in geographical areas where CE Standards apply, but may be optional in other locations.
1
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.
2
Options include oil-resistant rubber pads for use on oily surfaces and pads with closed-cell foam rings for use on rough or
textured surfaces (see REPLACEMENT PARTS LIST).