beautypg.com

Confirming the pad frame configuration, Pply the, Ads to a – Wood’s Powr-Grip MTCL8FS10TDC User Manual

Page 17: Powering up the lifter

background image

Rev 6.0/12-13

15

15

MTCL8HV11FDC: #35079

CAUTION: Examine each air filter regularly, and empty when necessary.

Two air filters help protect the vacuum generating system from contaminants. However, the

lifter is not intended for use on wet load surfaces because the filters would not necessarily

prevent liquid from entering the vacuum system. In order for a filter to function, the operator
must empty the filter bowl before enough liquid accumulates to contact any portion of the filter
element (see MAINTENANCE: A

IR

F

ILTER

M

AINTENANCE

).

Confirming the Pad Frame Configuration

WARNING: Load Capacity of lifter varies, depending on pad frame configuration.

Make sure the pad frame has been assembled in the configuration that will provide optimal

support of the load while lifting (see ASSEMBLY: T

O

C

HANGE THE

P

AD

F

RAME

C

ONFIGURATION

). The

pad frame configuration selected must be appropriate both for the weight and for the dimensions
of the load to be lifted.

Preparing to Use the Optional Remote Control System

If the lifter is equipped with a Remote Control System, the operator can engage the lifter's apply

and release functions at distances up to 250 ft [76 m], provided there is a direct and clear view
of the lifter and its status indicators from the operator location (see MAINTENANCE: R

EMOTE

C

ONTROL

S

YSTEM

T

EST

). When lifting a load from a remote location, the operator must monitor the

lifter at all times to make sure that it is functioning as intended.

4

In addition, the operator must

exercise special care to ensure that the load is landed and supported correctly before releasing
the load (see T

O

R

ELEASE THE

P

ADS FROM THE

L

OAD

to follow).

The radio transmitter is also equipped with an emergency transmitter disconnect that prevents

the transmitter from sending any transmission. This button should not need to be used, but may

have to be reset if accidentally engaged. To reset, twist the button clockwise while allowing it to
spring outward to its normal position.

T

O

A

PPLY THE

P

ADS TO A

L

OAD

Powering up the Lifter

Place the lifter's power switch in the ON ( ) position.

5

The blue power light remains

illuminated while the lifter is powered up. Keep the power switch in the ON position while lifting
a load. Any power interruption during a lift could result in the release of a load and possible

injury to the operator or others (see T

O

L

IFT AND

M

OVE THE

L

OAD

: In Case of Power Failure to

follow).

WARNING: Never turn power off while lifting.

4

The Remote Control System is designed with safeguards to prevent multiple lifters from responding until a clear transmission is

received. Nevertheless, radio controlled lifters should be tested to ensure that each transmitter controls only one lifter. The

buttons located on the lifter function regardless of any radio transmissions in the vicinity.

5

When the operator powers up the lifter, either the stand-by function or the apply function is automatically activated, depending

on which was used last. If a vacuum pump or any other powered component fails to function while the lifter's power switch is in

the ON position, examine each circuit breaker (adjacent to power switch) to determine whether it has interrupted the electrical
circuit to the component. Although the operator can reset the circuit breaker, the power interruption may indicate an electrical

problem that requires attention. Correct any deficiency before resuming normal operation of the lifter (see wiring diagram
provided).