Specifications – Wood’s Powr-Grip MT5HV11AC User Manual
Page 5

Rev 19.0/1-14
3
MT5HV11AC: #35086
SPECIFICATIONS
Model Number:
MT5HV11AC
Description:
Designed for use with a crane or other hoisting equipment, the MT5HV11AC
lifter employs vacuum to hold a load for lifting, and it provides manual 90°
tilt movement for load manipulation.
Power Source:
See serial number plate for specific AC voltage, frequency and amperage.
Vacuum Pads:
Five 10" [25 cm] nominal diameter, lipped (Model HV11), standard rubber,
spring-mounted (¼" [7 mm] travel), with #60 filter screen; Optional closed-
cell foam rings for applications on rough or textured surfaces.
Maximum Pad Spread:
22½" x 46" [572 mm x 1168 mm] to outer edges
Load Capacity:
(rated at 17½" Hg [-59 kPa] on clean, smooth, nonporous flat surfaces
1
)
Per-Pad:
160 lbs [73 kg]
Maximum:
800 lbs [365 kg]
Lifter Weight:
101 lbs [46 kg]
Tilt Capability:
Manual, 90°
Vacuum Pump:
Diaphragm type, 3 SCFM [85 liters/minute] nominal airflow
Vacuum Reserve:
Vacuum reserve system helps prevent immediate vacuum loss in case of
power failure.
Vacuum Gauge:
Dial gauge indicates current vacuum level in positive inches of Hg and
negative kPa.
Options:
See separate instructions about optional features.
Operating Elevation:
Maximum = 7000 feet [2133 meters]
Operating Temperatures: 32° to 100° F [0° to 38° C]
Service Life:
This lifter is designed to have a service life of at least 20,000 lifting cycles,
when used and maintained as intended. Vacuum pads, filter elements and
other wear-out items are excluded; see MAINTENANCE and REPLACEMENT
PARTS LIST for more information. For the D
ISPOSAL OF THE
L
IFTER
after its
service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.powrgrip.com for more
information)
!!-CE-!! Note: This symbol appears in the
INSTRUCTIONS
manual only when requirements of a CE Standard are
different
from requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory
in geographical areas where CE Standards apply, but may be optional in other locations.
1
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.