U32-5 FPI Direct Vent Gas Insert

19

INSTALLATION

Installation of the DC Sparker:

16)

Verify that if the conversion is from

NG to LPG, the screw must be re-

assembled with the red o-ring visible

(Fig. 5).

LPG Configuration

Red o-ring visible

Fig.5

17)

Re-assemble the black protection

cap (Fig. 6).

Fig. 6

WARNING!

Also check that the pilot and main

burner injectors are appropriate for

the gas type.

19)

Attach the label "This unit has been

converted to LPG" near or on top of the

serial # decal.

20)

Replace yellow "NG" label with red

"LPG" label.

21)

Locate the Piezo Ignitor situated at the

side of valve.

22)

Remove the Piezo Ignitor by unscrewing

the nut at the back of the mounting

bracket.

23)

Disconnect the ignitor wire from the

Piezo Ignitor and connect it to the DC

Sparker.

Piezo

Ignitor

Ignitor

Wire

Piezo

Ignitor

Ignitor

Wire

DC

Sparker

18)

Reverse steps 6 - 1.

Fig. 1

11)

Remove the black

protection cap by hand

from the hi-low knob

(Fig.1).

Fig.2

14)

Flip the screw (Fig. 3).

Fig.4

Fig.3

15)

Using the Allen wrench

as shown in Fig.4, rotate

the screw clockwise until

snug, do not overtighten.

12)

Insert a 5/32” or 4mm

Allen wrench into the

hexagonal key-way

of the screw (Fig.

2), rotate it counter-

clockwise until it is free

and extract it.

13)

Check that the screw is clean and if

necessary remove dirt.

WARNING!

Do not over tighten the screw.

Recommended to

grip the wrench by the short side.

24)

Connect the DC spark generator wires

to the SIT Valve with the screw, which is

provided in the kit.

18a)

Install the air defl ector to the back wall of

the fi rebox using 2 screws.

Air Defl ector

For U32-5 Only:

9)

Reinstall new burner orifi ce LPG

stamped #52 and tighten.

10)

Turn control knob to the “OFF” position.