Energy saver – Bock Water heaters Energy Saver 80PDVILN-150 User Manual
Page 2
www.bockwaterheaters.com
110 South Dickinson Street , Madison, Wisconsin 53703
Toll Free 800.794.2491
•
Phone 608.257.2225
●
Fax 608.257.5304
80029 Rev 6/08
Natural Gas use the suffix "NA", Example: 80PDVI-150-NA
LP on 80PDVI-250 and 100PDVI-250 only. Use suffix "XA" to order. Example: 80PDVI-150-XA
ASME Construction available on the 80PDVI-250 and 100PDVI-250 only; Use suffix "A" to order; Example: 80PDVI-250-NA-A
For Low NOx compliance to meet SCAQMD requirements, place an "LN" in the model number; Example: 80PDVILN-250-NA
T=Top, F=Front, R=Rear
These models meet or exceed the Thermal Efficiency and Standby Loss Requirements of ASHRAE 90.1b current standard.
115V A.C. Required
T&P Valve, Brass Drain Valve, Dielectric Fittings, Magnesium Anode Rods: Factory Installed
Pressures (all): Working Pressure, 150 psi; Tested Pressure, 300 psi
Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z21.10.1.
Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or anti-scald
valve be installed and used according to the manufacturer’s directions to prevent scalding.
Energy Saver
P
ower
D
irect
V
ent
I
ndependent Vent System
Gas Water Heaters
This product is available from:
MODEL
NUMBER
STORAGE
(GAL)
RATED
INPUT
(BTU/HR)
1ST HR
DEL GAL
@ 100
° F
RISE
RECOVERY GPH
@ DEGREE RISE
DIMENSIONS (INCHES)
SHIPPING WEIGHT
A
HEIGHT
B
DIA.
C
TOP
WATER
CONN.
D
F&R
HOT
CONN.
E
F&R
COLD
CONN.
F
GAS
CONN.
G
TOP
VENT
HEIGHT
WATER
CONN.
GAS
CONN.
DIA.
RELIEF
VALVE
OPEN.
STD
(LBS)
ASME
(LBS)
40
° F 100° F 140° F
80PDVI-150
80
150,000
204
364
145
104
63-1/2
28-1/4
65-1/8
51-5/16 20-3/16 17-1/4
68-3/16
1-1/12(T&F)
2(R)
3/4
3/4
645
N/A
80PDVI-200
80
199,999
253
485
194
139
63-1/2
28-1/4
65-1/8
51-5/16 20-3/16 17-1/4
68-3/16
1-1/12(T&F)
2(R)
3/4
3/4
645
N/A
80PDVI-250
83
250,000
301
606
242
173
63-1/2
28-1/4
65-1/8
51-5/16 20-3/16 17-1/4
73-1/16
1-1/12(T&F)
2(R)
3/4
1
645
720
100PDVI-150
100
150,000
219
364
145
104
74-1/8
28-1/4
74-1/8
60-5/16 20-11/16 17-1/4
77-3/16
1-1/12(T&F)
2(R)
3/4
3/4
735
N/A
100PDVI-200
100
199,999
266
485
194
139
74-1/8
28-1/4
74-1/8
60-5/16 20-11/16 17-1/4
77-3/16
1-1/12(T&F)
2(R)
3/4
3/4
735
N/A
100-PDVI-250
100
250,000
312
606
242
173
74-1/8
28-1/4
74-1/8
60-5/16 20-11/16 17-1/4
82-1/16
1-1/12(T&F)
2(R)
3/4
1
735
815
Propane Gas Inputs (LP)
1ST HR.
DEL GAL.
@ 100° F
RISE
RECOVERY GPH @
DEGREE RISE
40° F
100° F
140° F
80PDVI-250-XA 225,000 BTUH
274
545
218
156
100PDVI-250-XA 225,000 BTUH
288
545
218
156
(LN) LowNOx Burners
1ST HR.
DEL GAL.
@ 100° F
RISE
RECOVERY GPH @
DEGREE RISE
40° F
100° F
140° F
80PDVILN-150
150,000 BTUH
201
364
145
104
80PDVILN-200
180,000 BTUH
250
436
175
125
80PDVILN-250
220,000 BTUH
298
533
213
152
100PDVILN-150 150,000 BTUH
215
364
145
104
100PDVILN-200 180,000 BTUH
245
436
175
125
100PDVILN-250 220,000 BTUH
283
533
213
152