ASTM C547
Standard Specification for Mineral
Fiber Preformed Pipe Insulation
Type I, II, IV, V
Grade A
Maximum Surface Temperature
ASTM C411
Hot Surface Performance
In Compliance with ASTM C547
@
1400 °F (760 °C)
ASTM C447
Maximum Surface Performance
In Compliance with ASTM C547
@
1400 °F (760 °C)
Dimension Stability
ASTM C356
Linear Shrinkage
0.60%
@
1200 °F (650 °C)
Compressive Strength
ASTM C165
at 10%
1102 psf (52.8kPa)
at 25%
1906 psf (91.3 kPa)
Density
ASTM C303
11.25 lbs/ft
3
180 kg/m
3
Acoustical Performance
ASTM E1222 – Standard Test Method For Laboratory Measurement of the Insertion Loss of Pipe Lagging
Product
Jacket
Frequency (Hz)
800
1000
2000
4000
5000
Insertion Loss (db)
12 x 1.5
Aluminum
0
5
8
18
24
Stainless Steel
1
5
14
21
28
PVC
0
2
9
21
28
12 x 2
Aluminum
0
5
10
19
26
Stainless Steel
1
10
16
24
31
PVC
0
1
12
23
30
12 x 2.5
Aluminum
1
7
10
25
30
Stainless Steel
1
11
14
26
33
PVC
0
3
8
25
31
12 x 3
Aluminum
0
3
14
23
30
Stainless Steel
1
6
17
27
33
PVC
0
3
10
26
29
12 x 4
Aluminum
3
14
13
25
31
Stainless Steel
5
14
16
28
34
PVC
0
8
16
26
31
ProRox
®
PS 980
NA
NEW
NAME