Connect to the gas supply

The inlet to the cooker is

1

2

” BSP

internal situated at the rear right corner.
Fit the bayonet connection. This should
be located so as to ensure that the
flexible connector hose does not kink.
Use a 900-1125mm length of flexible
connector.
Ensure that all pipe work is of the correct
rating for both size and temperature.
Flexible connections should comply
with BS 669. Parts of the appliance
likely to come into contact with a
flexible connector have a temperature
rise of less than 70˚C.
After installation, make sure all
connections are gas sound.

Commissioning

Burner aeration
All burners have fixed aeration and no
adjustment is possible.

Pressure setting
G20 Natural Gas @ 20 mbar

Pressure test point
Use the oven injector

Hob - Turn the control knob to the

FULL

ON

position, wait a second before

pressing the ignition switch or holding
a lighted match or taper to the burner.

Before leaving the installation
1. Place all the loose parts of the

cooker into position.

2. Show the customer how to operate

the cooker and give them this
handbook. Thank you.