beautypg.com

Bryan electric hot water or steam boilers, Bryan bh series boiler specifi cations – Bryan Boilers 390BHW4T7 User Manual

Page 2

background image

Bryan electric hot water or steam boilers...

For commercial, institutional and industrial applications

Bryan BH Series Boiler Specifi cations

Model

Input KW

MBH BHP lbs/hr

(kg/hr)

Water

lbs (kg)

Steam

lbs (kg) Input

KW

MBH BHP lbs/hr

(kg/hr)

Water lbs (kg)

Steam lbs (kg)

60BH

196

6

207 (93)

900 (408)

1,000 (454)

660BH

2,156

66

2,277 (1,033) 3,350 (1,520) 3,600 (1,633)

75BH

245

7.5

259 (117)

900 (408)

1,000 (454)

720BH

2,352

72

2,484 (1,127) 3,500 (1,588) 3,800 (1,724)

90BH

294

9

311 (141)

1,000 (454)

1,100 (499)

780BH

2,548

78

2,691 (1,221) 3,600 (1,633) 4,000 (1,814)

105BH

343

10.5

362 (164)

1,000 (454)

1,300 (590)

840BH

2,744

84

2,898 (1,315) 3,700 (1,678) 4,100 (1,860)

120BH

392

12

414 (187)

1,000 (454)

1,300 (590)

900BH

2,940

90

3,105 (1,408) 3,850 (1,746) 4,200 (1,905)

135BH

441

13.5

466 (211)

1,200 (544)

1,400 (635)

960BH

3,136

96

3,312 (1,502) 4,000 (1,814) 4,400 (1,996)

150BH

490

15

518 (234)

1,200 (544)

1,400 (635)

1020BH

3,332

102

3,519 (1,596) 4,500 (2,041) 5,000 (2,268)

165BH

539

16.5

569 (258)

1,300 (590)

1,500 (680)

1080BH

3,528

108

3,726 (1,690) 4,500 (2,041) 5,100 (2,313)

180BH

588

18

621 (281)

1,300 (590)

1,500 (680)

1140BH

3,724

114

3,933 (1,784) 5,000 (2,268) 5,500 (2,495)

195BH

637

19.5

673 (305)

1,400 (635)

1,700 (771)

1200BH

3,920

120

4,140 (1,878) 5,250 (2,381) 5,700 (2,586)

210BH

686

21

725 (328)

1,400 (635)

1,700 (771)

1260BH

4,116

126

4,347 (1,972) 5,500 (2,495) 6,000 (2,722)

225BH

735

22.5

776 (352)

1,500 (680)

1,800 (816)

1320BH

4,312

132

4,554 (2,066) 5,600 (2,540) 6,100 (2,767)

240BH

784

24

828 (375)

1,600 (726)

1,900 (862)

1380BH

4,508

138

4,761 (2,160) 5,700 (2,586) 6,300 (2,858)

270BH

882

27

932 (422)

1,600 (726)

2,000 (907)

1440BH

4,704

144

4,968 (2,253) 5,800 (2,361) 6,400 (2,903)

300BH

980

30

1,035 (469)

1,700 (771)

2,200 (998)

1530BH

4,999

153

5,279 (2,394) 6,000 (2,722) 6,600 (2,994)

330BH

1,078

33

1,139 (516)

1,800 (816)

2,300 (1,043)

1620BH

5,293

162

5,589 (2,535) 6,200 (2,812) 6,800 (3,084)

360BH

1,176

36

1,242 (563)

1,800 (816)

2,400 (1,089)

1710BH

5,587

171

5,900 (2,676) 6,400 (2,903) 7,000 (3,175)

390BH

1,274

39

1,346 (610)

2,000 (907)

2,500 (1,134)

1800BH

5,881

180

6,210 (2,817) 6,600 (2,994) 7,200 (3,266)

420BH

1,372

42

1,449 (657)

2,000 (907)

2,600 (1,179)

1920BH

6,273

192

6,624 (3,005) 6,800 (3,084) 7,400 (3,357)

450BH

1,470

45

1,553 (704)

2,100 (953)

2,700 (1,225)

2040BH

6,665

204

7,038 (3,192) 7,000 (3,175) 7,600 (3,447)

480BH

1,568

48

1,656 (751)

2,150 (975)

2,800 (1,270)

2160BH

7,057

216

7,452 (3,380) 7,200 (3,266) 7,800 (3,538)

510BH

1,666

51

1,760 (798)

2,500 (1,134) 2,900 (1,315)

2280BH

7,449

228

7,866 (3,568) 7,400 (3,357) 8,100 (3,764)

540BH

1,764

54

1,863 (845)

2,500 (1,134) 3,000 (1,361)

2400BH

7,841

240

8,280 (3,756) 7,600 (3,447) 8,300 (3,765)

600BH

1,960

60

2,070 (939)

3,000 (1,361) 3,500 (1,588)

NOTES: * Lbs. steam per hour from and at 212°F. ** Not intended for use as a principal heating source for living space of any individual residence.

Effi ciency

Bryan Electric Boilers are nearly 95% effi cient at all load levels.
Varying loads do not effect the effi ciency since the resistive type
heating elements are immersed and designed to heat the water
directly. With a modulating step control only the elements that
are required to heat the water to the desired temperature/
pressure will be energized in order to encourage a balanced
load during operation.

Replaceable Hairpins

Each element hairpin is fi eld replaceable with no welding,
soldering, or brazing required. Each hairpin, as standard for
all Bryan Electric Boilers, is Incoloy sheathed and industrial size
0.430

؆ diameter. Elements are designed for 75 watts/sq. inch

for long life (optional 50 W/D available). Elements are individually
installed in a standard ANSI 150 lb. blind fl ange.

Steam Disengaging Area

Steam release area is near the middle of the horizontal vessel
for maximum steam disengaging area for dry steam and stable
water level.

Water Boiler Design

Vessel is designed for proper circulation around individual
elements to maximize heat transfer. High velocities, i.e. heat
pump applications, are handled with very little pressure drop
when using a horizontal tank for the pressure vessel. Supply
and return nozzle sizes can be made larger to accommodate
the fl ow requirements. Pressure drop is minimal through the
boiler and no dangers are involved with low fl ow conditions.

Bryan Series BH Electric hot water** or steam boilers are
compact, completely packaged and wired units with automatic
controls and featuring long life Incoloy sheathed elements.
Applications include hot water heating, steam heating, process
heating, and supplemental heat for heat pump type equipment.
All Bryan Boilers are built in accordance with the requirements
of the ASME boiler and pressure vessel code and are UL listed.
Water boilers are 150 psig MAWP and steam boilers either 15
psig or 150 psig. Higher pressures are available.

Electric Element Bundle

Each element
replaceable with
hand tools. Incoloy
sheathed, 75 watts/
sq. in.

Spacing disc
for support and
proper circulation
around individual
elements

Removable
threaded fi ttings
for ease of indi-
vidual element
replacement

150 lb. ANSI fl ange

Water boiler trim and controls

Steam boiler trim and controls

Step
indicating
lights

Control panel

Lifting
lugs

ASME
relief
valve

Pressure and
temperature
gauges

(2) High
limit controls

Drain

Operating
control

Probe type low
water cutoff
control

Power
panel

Fused control
circuit
transformer

Blowdown

Fused control
circuit
transformer

Step
Indicating lights Control panel

Power
panel

Lifting
lugs

Standard Equipment Supplied:

HOT WATER DESIGN BOILERS:

Model “W” (150# ASME Design)

Temperature and pressure gauge, Operating

immersion aquastat, 2 high limit aquastats, Low

water cutoff, Relief valve, Metal jacket with 4

؆

fi berglass, 75 W/D Incoloy sheathed elements with

pressure connector power lugs. Separate power panel
and control panel, On/Off control switch, 120 volt
control transformer (fused), Magnetic contactors with
120 volt coil, Individual circuit Class JKS fusing, step
indicating lamps, First on/fi rst off progressive step
controller, National Board Inspection and UL Label.

Power Circuit Design:

All Bryan BH Series boilers feature copper bus bar distri-
bution, wherein the fuse clip for each branch circuit and
the main power lugs are all bolted directly to a bus bar.
The bus bar can carry the full load current of the
boiler, withstanding the largest available fault
current from the entering power system. Use of
the bus bar protects all current-carrying parts
and prevents damage to the boiler.

Optional Equipment Available:

Power panel door electric interlock. Preheat
switch. Flow switch. Manual reset controls.
Manual blowdown valve. Automatic blowdown
with 24 hour time clock. Alarms. Indicating lights.
Larger connection for heat pump applications.

Other Designs Available:

1) BE – Economical Electric Boilers

(Form 3600)

2) WT – Indirect Hot Water Supply Heaters
(Form

4800)

Standard Equipment Supplied:

STEAM DESIGN BOILERS:

Model “S” (15# ASME Design)

Model “Q” (150# ASME Design)

Steam pressure gauge w/gauge clock, Operating

pressure control, 2 high limit pressure controls,

Combination low water cutoff and pump control,
Auxiliary low water cutoff, Relief valve, Water glass
set, Metal jacket with 4

؆ fi berglass, 75 W/D Incoloy

sheathed elements with pressure connector power
lugs. Separate power panel and control panel,

On/off control switch, 120 volt control transformer
(fused), Magnetic contactors with 120 volt coil,

Individual circuit Class JKS fusing, Step indicating
lamps, First on/ fi rst off progressive step controller,
National Board Inspection and UL Label.

Standard Design Features

Nom. Output

Steam Output*

Approx. Shipping Weight

Model

Nom. Output

Steam Output* Approx. Shipping Weight

ASME
relief
valve

Pressure
gauge

Probe type
low water
cutoff control

(2) high limit
controls

Operating
control

Water level
gauge glass

Low water
cutoff and
pump control

Heavy duty 11
gauge power
panel cabinet

Single point
electric
connection

Each branch
circuit is fused
individually using
copper bus bar
for power
distribution

Separate
control panel
for 120V
controls

4" channel base

Louvered panel cover for
proper cooling air circulation

Immersion heating
bundles broken down in
150 KW bundles or less

Hinged
access
door for
access
to vessel,
ASME and
elements

4" fi berglass
insulation

16 gauge jacketing all
around structural frame
(zinc-coated rust
resistant primer and
enamel fi nished)

This manual is related to the following products: