Example daisy chain setup, Compatibility with other fuels – PLX Devices SM-AFR User Manual
Page 2

TERMS OF USE
PLX Devices Inc. does not guarantee product functionality
with any ECU, data logger or other devices that uses the
output signals. Implementation and integration of the PLX
products with any other device(s) must be done at your own
risk. Improper installation and usage may lead to engine
damage. Mount and install PLX products in a location
where it does not obstruct the driver’s view and/or ability to
safely control the vehicle.
PLX Devices Inc. does not guarantee product functionality
with ALL vehicles. Implementation and integration of the
PLX products with any other device(s) must be done at your
own risk. Improper installation and usage may lead to en-
gine damage. Mount and install PLX products in a location
where it does not obstruct the driver’s view and/or ability or
safely control the vehicle
LIMITED WARRANTY
PLX Devices Inc. warrants this product to be free from
defects for 1 year from the date of purchase. If applicable,
Oxygen sensors and other non-serviceable items are
excluded from stated warranty. Serviceable goods must
be determined by PLX Devices to be defective before any
warranty or replacement is issued. PLX Devices’ obligation
under warranty shall be limited to repairing or replacing,
under the discretion of PLX Devices, any part proven defec-
tive. This warranty is limited to the repair or replacement
of parts in the manufactured good and the necessary labor
done to affect its repair or replacement.
SERVICE UNDER WARRANTY
In the unlikely event that your PLX Devices hardware
should fail during the warranty period, a Return Material
Authorization number (RMA) must be first retrieved from
PLX Devices Customer Support. Support can be contacted
through email: [email protected] or by phone: 408-745-
7591. All serviceable goods must be packaged securely with
proof of purchase, RMA number, with all shipping charges
prepaid and shipped to PLX Devices Inc. Goods returned
under warranty must be received by PLX Devices Inc.
within ten (10) business days after the RMA number has
been issued. Goods received after this period are subject to
fees for the service of repair or replacement. All repaired or
replaced items shall be warranted for the remainder of the
original product warranty.
RETURNS AND RESTOCKING FEE
All returns must be within 30 days of receipt. A 15%
restocking fee may be assessed to applicable PLX Devices
products for refund. All returns are to be packed in original
condition including packaging, documentation, manuals,
and accessories. Returns that do not include all the acces-
sories and components may be returned to the customer
or charged on a per item basis. The customer assumes
responsibility for product until receipt at PLX Devices Inc.,
shipping via an insurable carrier is recommended. Any un-
authorized shipping charges will be billed to the customer
or shipment will be refused.
DISCLAIMER
PLX Devices Inc. shall not be liable for direct, special, inci-
dental, or consequential damages resulting from any legal
theory including, but not limited to, lost profits, downtime,
goodwill, damage, injury to persons, or replacement of
equipment and property due to improper installation, inte-
gration and/or misuse of any PLX Devices Inc.’s product(s).
This warranty applies to the original purchaser of product
and is non-transferable. All implied warranties shall be
limited in duration to the said 1 year warranty period.
Physical Dimensions
Technology
Accuracy
Measurement Range
Analog Outputs
Operating Voltage
Power Consumption
Power Supply Technology
Operating Temperature
Sensor
Enclosure
2 x 2.875 x 1.125” (52 x 75 x 28mm) L x W x H
PLX Critical Response Technology, Fast Response PID
< 0.1AFR (Gasoline) Wideband, < 0.2AFR (Gasoline) Narrowband
10-20 AFR, 0.68 lambda - 1.36 lambda
Wideband Linear 0-5V, Narrowband 0-1V (Driving Current 20mA)
9V-20V
30 Watts (Max), 18 Watts (Typical)
High Efficiency Switching with Soft Start Technology
0 - 85 Deg C
One Bosch LSU 4.2
Extruded Aluminum
Specifications:
Included Items:
1. SM-AFR main unit
2. Bosch LSU 4.2 wideband sensor
3. O2 sensor harness 10”
4. 4” power wire with 2.1mm connector
5. 4” Analog wires and connector with 4 terminals
6. 1” Serial Cable
7. Termination jumper
8. Users guide
Troubleshooting:
Upon power up, the WB analog output should read 2.30V-2.40V with the O2 sensor disconnected. With
the O2 sensor connected and exposed to free air, the WB analog output should read starting from 2.3V
climbing up to 5.0V within 30 seconds. If both conditions are met, your SM-AFR is properly working. If
the sensor does not reach Lean/Air within 45-60 seconds, please replace your O2 sensor. Replacement sen-
sors are available from the PLX Online Store under accessories.
1. The output is not showing the correct AFR readings:
A. With the O2 sensor harness disconnected, at initial power-up it should display between 14.6 and 14.7
(wideband analog voltage: 2.30V - 2.40V).
i. If it is reading below 14.5, please verify that the unit is receiving at least 12V and you have at least a 5
amp fuse. If it is still reading below 14.5 even with the correct voltage, contact
and
request a RMA number. Your unit is faulty and needs to be repaired.
ii. If it is reading above 14.8, contact
and request a RMA number. Your unit is
faulty and needs to be repaired.
B. Reconnect the O2 sensor with the sensor harness, with the O2 sensor exposed to free air. During the
30 second warm up phase, the voltage should increase from 2.35V to 5.0V.
i. Voltage does not read 5.0V even after 60 seconds:
a. Try another power source for your SM-AFR.
b. Verify that a fuse is installed rated no less than 5A.
c. Check connectivity of harness and O2 sensor.
d. Your O2 sensor needs to be replaced.
C. When the unit says AIR*, blow on the O2 sensor. The display should show LEAN*.
i. Display does not go to LEAN*:
a. Your O2 sensor needs to be replaced.
* will only show “LEAN” or “AIR” on DM-6 Gauge
Compatibility with Other Fuels:
The above graphs assume that the device will be used with gasoline (14.7). The SM-AFR is also
compatible with the following fuels: Diesel (14.6), Methanol (6.4), Ethanol (9.0), LPG (15.5),
CNG (17.2), E85 (9.7). To find the new relationship of AFR to output voltage, simply multiply
the lambda value by the specific fuel’s stoichiometric air/fuel ratio.
Example: If your engine uses methanol instead of gasoline, the conversion will be as follows.
1) Divide the AFR value by 14.7 (gasoline) to obtain a lambda value
2) Multiply the lambda value by 6.4 (methanol)
Lambda
0.68
0.80
0.90
1.00
1.10
1.20
1.30
1.36
Gasoline
10.00
11.76
13.23
14.70
16.17
17.64
19.11
19.99
Diesel
9.93
11.68
13.14
14.60
16.06
17.52
18.98
19.86
Methanol
4.35
5.12
5.76
6.4
7.04
7.68
8.32
8.70
Ethanol
6.12
7.20
8.10
9.00
9.90
10.80
11.70
12.24
E85
6.60
7.76
8.73
9.70
10.67
11.64
12.61
13.19
LPG
10.54
12.40
13.95
15.50
17.05
18.60
20.15
21.08
CNG
11.70
13.76
15.48
17.20
18.92
20.64
22.36
23.39
Example Daisy Chain Setup
Remove termination jumpers from all sensor modules excluding sensor module furthest from
display modules.