Fault

Remedial action

Possible cause

Ice maker is not producing any ice.

The ice cube container is in the false

position.

Reinsert the container and slide it backwards to the end

position (see section Variable interior design").

The water pressure is too low.

Check water pressure. The water pressure must be

between 25 and 120 p.s.i. (1.72ć8.25 bar).

The freezer compartment temperature

is too high.

Check temperature of the freezer compartment.

If required, lower the temperature.

A wrong water valve has been

installedt.

SelfĆtapping valves and 3/16 inch (4.76 mm) saddle

valves reduce the water pressure and may eventually

block the pipe.

The manufacturer is not liable for damage to

property due to an incorrect installation or water

connection.

The ice maker is not producing

enough ice or the ice cubes are

The water pressure is too low.

Check water pressure. The water pressure must be

between 25 and 120 p.s.i. (1.72ć8.25 bar).

g

misshapen.

The freezer compartment temperature

is too low.

Check temperature of the freezer compartment.

If required increase the temperature.

Change the water filter.

Instructions for changing the water filter can be found in

the enclosed installation instructions.

Ice is forming in the supply hose to

the ice maker.

The water pressure is too low.

Check water pressure. The water pressure must be

between 25 and 120 p.s.i. (1.72ć8.25 bar).

The freezer compartment temperature

is too high.

Check temperature of the freezer compartment.

If required, lower the temperature.

Water is flowing out of the

appliance.

The water pipe in the appliance is

defective.

Call customer service immediately.

pp

è Close shutĆoff valve immediately.

The water pressure is too low.

The valve may leak if the water pressure is too low.

The water pressure must be between 25 and 120 p.s.i.

(1.72ć8.25 bar).

A wrong water valve has been

installed.

SelfĆtapping valves and 3/16 inch (4.76 mm) saddle

valves reduce the water pressure and may eventually

block the pipe.

The manufacturer is not liable for damage to

property due to an incorrect installation or water

connection.