Characteristics, Characteristics electrical characteristics, Mechanical characteristics – Northern Connectors Radiall SMB Series Coaxial Connectors User Manual
Page 22: Environmental characteristics, Materials and plating
www.radiall.com
7-22
SMC
CHaRaCTERISTICS
ElECTRICal CHaRaCTERISTICS
Impedance
50Ω
Frequency range
DC - 10 GHz
V.S.W.R. (typ.)
Straight
Right angle
cable
3-14
2/50
1.25 + 0.04 F (GHz)
1.40 + 0.06 F (GHz)
2.6/50
1.20 + 0.04 F (GHz)
1.30 + 0.04 F (GHz)
Insertion loss
Straight
Right angle
3-27
0.25 dB max. at 4 GHz
0.5 dB max. at 4 GHz
RF leakage
3-26
-60 dB min between 2 and 3 GHz
Insulation resistance
3-11
1000 MΩ min
Contact resistance
• center contact (mΩ)
• outer contact (mΩ)
3-16
Initial
6
1
After environment
8
1.5
Voltage rating (volts RMS)
• at sea level
• at 70000 ft (21000 m)
cable
2/50
250 V rms
60 V rms
2.6/50
335 V rms
85 V rms
Dielectric withstanding voltage
• at sea level
• at 70000 ft (21000 m)
cable
3-17
2/50
750 V rms
185 V rms
2.6/50
1000 V rms
250 V rms
RF high potential withstanding
voltage (Frequency 5 MHz)
• at sea level
cable
3-23
2/50
500 V rms
2.6/50
700 V rms
MECHaNICal CHaRaCTERISTICS
Durability
3-15
500 matings
Force to engage and disengage
3-5-1
torque: 16 inch-ounces max - 11.3 Ncm
Mating torque
35 to 50 inch-ounces - 25 to 35 Ncm
Coupling nut proof torque
100 inch-ounces - 71 Ncm
Coupling nut retention force
3-25
35 Ibs min - 156 N min
Cabling retention force
cable
3-24
2/50
13 Ibs - 58 N
2.6/50
25 Ibs - 110 N
Contact captivation
Axial force: 4 Ibs - 18 N torque: not applicable
ENVIRONMENTal CHaRaCTERISTICS
Operating temperature range
standard models and hermetic
models for semi-rigid cables
-65°C / + 165°C
-65°C / +105°C
Temperature cycling
MIL-STD-202, method 102, condition C
Thermal shock
3-20
MIL-STD-202, method 107, condition B
High temperature test
MIL-STD-202, method 108
Corrosion (salt spray)
3-13
MIL-STD-202, method 101, condition B, 5%
Vibration
3-18
MIL-STD-202, method 204, condition D, 20g
Shock
3-19
MIL-STD-202, method 213, condition C, 100g
Moisture resistance
3-21
not applicable
Barometric pressure
3-22
MIL-STD-202, method 105, condition C
Hermetic test
Down to 10
-6
mm Hg (Torr)
Leak rate <1 x 10
-6
atm/cm
3
/sec
MaTERIalS aND PlaTINg
Material
Plating
Bodies and male contacts
Brass, half hard per QQ-B-626
Gold to satisfy the corrosion
requirements (bodies)
Female contacts and interfaces
Beryllium copper per QQ-C-530
Gold (Center contact)
Ferrules
Brass
Insulators
PTFE teflon
Gaskets
Silicone rubber
All dimensions are given in mm
Test/characteristics
MIL-C-39012 paragraph
Values/remarks