Hook-up wire – Northern Connectors Alpha Wire Hook-Up Wire User Manual
Page 26
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
398
Wire > Hook-Up Wire > 1000/300 V
Hook-Up Wire
1000/300 V, PTFE
MIL-DTL-16878/5 (TYPE EE)
(1000V)
UL AWM 1180 (300V)
NEMA HP3
Operating Temperature
• -60°C to +200°C
Materials
• Stranded or solid silver-plated
copper conductor
• PTFE insulation
Availability
100 ft (30.5 m)
1000 ft (305 m)*
*May contain multiple lengths
Part No.
Wire Size
Stranding
Insulation
Thickness
Nominal
Diameter
NEMA
HP3
Type
AWG
mm
2
AWG
mm
Inch
mm
Inch
mm
5874
24
0.24
19/36
19 x 0.13
0.015
0.37
0.054
1.37
EEXBEE
5875
22
0.38
19/34
19 x 0.16
0.014
0.36
0.060
1.52
EEXBFE
5876
20
0.62
19/32 19 x 0.20
0.014
0.36
0.068
1.73
EEXBGE
5877
18
0.96
19/30 19 x 0.25
0.015
0.37
0.079
2.01
EEXBHE
5878
16
1.23
19/29 19 x 0.29
0.016
0.41
0.089
2.26
EEXBJE
5879
14
1.94
19/27 19 x 0.36
0.017
0.43
0.106
2.69
EEXBKE
5879/10
10
4.74
37/26 37 x 0.40
0.017
0.43
0.145
3.68
EEXBMG
5879/12
12
3.08
19/25
19 x 0.45
0.017
0.43
0.125
3.18
EEXBLE
5879/8*
8
8.61
133/29 133 x 0.29
0.020
0.51
0.209
5.31
EEXBNL
*Not UL AWM 1180.
Insulation Colors
White
Yellow
Slate
Black
Blue
Violet
Red
Brown
Green
Orange