beautypg.com

Float switch (piggy-back) – Multiquip ST2040T User Manual

Page 13

background image

ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV. #3 (06/15/10) — PAGE 13

Float Switch

Single

or

dual

control float switches (Figure 6) can be used for the unattended operation of the submersible pump. When using the

piggy-back power configuration

(plug), the pumps DO NOT require the use of a control box. In this configuration

(piggy-back), the

SW-1 (single float switch) or SW-2 (dual float switch) are required. The illustration below is an example of a single float switch application.

ST2037, 47, 47B, 38P, 40T SUB. PUMP

FLOAT SWITCH (PIGGY-BACK)

Figure 6. Single Float Switch

Application Diagram

Figure 6 shows a

single float

switch

application. For dual float switch
capability use a

Model SW-2

mercury

type float switch .

NOTE

Mounting The Float Switch

1.

Determine the required

cord tether length

as shown in

Figure 6 and Table 3.

2.

Place the cord into the clamp as shown in Figure 6.

3.

Secure the clamp to the discharge hose as shown in Figure
5. DO NOT install cord under hose clamp.

4.

Using a screwdriver, tighten the hose clamp. DO NOT over-
tighten. Make sure the float cord is not allowed to touch the
excess hose clamp band during operation.

This manual is related to the following products: