Before Starting

1.

Read safety instructions at the
beginning of manual.

2. Place pump as near to water as

possible, on a firm flat, level surface.

3. To prime pump, remove fill cap (Figure 2) and fill pump casing

with water. If the pump casing is not filled with water before
starting, it will not begin pumping.

STOW CP-20H — PRE-SETUP (PUMP)

4. Check for

leaks

between pump and engine. If water is leaking

between the pump and engine housing, the seal inside the
pump may be worn or damaged. Continued operation of the
pump is not recommended. Further usage of the pump under
these conditions may cause severe water damage to engine.

Hoses and Clamps

1. Check that all hoses are

securely

attached to the pump.

Make certain suction hose (Figure 2) does not have any air
leakage. Tighten hose clamps and couplings as required.

2. It is recommended that 2 clamps be used when securing the

suction hose to the inlet side (suction) of the pump.

3. Remember suction hoses must be

rigid

enough not to

collapse when the pump is in operation.

4. Check that the discharge hose (Figure 2) is not restricted.

Place hose so that it lays as straight as it is possible on the
ground. Remove any twists or sharp bends from hose which
may block the flow of water.

CAUTION :

Pump casing

must be filled with water

before using pump. Otherwise pump will
not be able to begin pumping.

DO NOT open

fill cap if pump is hot! Water

inside may be under pressure.

WARNING :

NOTE

Suction and discharge hoses are
available from Multiquip. Contact
your nearest dealer for more
information.

5.

The discharge hose is usually a

collapsible (thin-walled)

hose, however if a thin-walled discharge hose is not avail-
able, a rigid suction hose can be substituted in its place.

6.

Make sure the

suction strainer (Figure 2) is clean and

securely attached to the water end of the suction hose. The
strainer is designed to protect the pump by preventing large
objects from being pulled into the pump.

CAUTION :

The strainer should be positioned so it will
remain completely

under water. Running the

pump with the strainer above water for long
periods can damage the pump.

CAUTION :

DO NOT pump flammable fluids, corrosive
chemicals or fluids containing toxic substances.
These fluids can create potentially dangerous
health and environmental hazards. Contact
local authorities for assistance.

CAUTION :

This pump uses a water-cooled

mechanical

seal

to prevent water from seeping into the

engine. The passage of water through the
pump casing lubricates the seal and prevents
it from overheating.

NEVER!

operate the pump

without water in the casing as this will cause
damage to the mechanical seal.