beautypg.com

Maintenance (pump) – Multiquip QPT305SLT User Manual

Page 20

background image

PAGE 20 — QP305SLT/QPT305SLT CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #3 (08/14/14)

PUMP VACUUM TEST

To perform the pump vacuum test do the following:
1. Remove the pump fill cap (See Figure 3), and fill the

pump with water.

2. Start the engine as outlined in the initial start-up

section, and wait for the pump to begin pumping.

3. As shown in Figure 18, place a water hose inside

the discharge opening of the pump, and turn on the

water. This flow of water into the discharge opening

will

prevent the pump from running dry.

4. Place the Pump Vacuum Tester (P/N 7000030) over the

pump suction (inlet) opening (See Figure 18) with the

vacuum gauge facing upwards. It may be necessary

to apply a small amount of water around the rubber

seal of the vacuum tester to make a good suction fit.

5. Check and make sure that there are no air leaks

between the vacuum tester and the inlet port on the
pump. If air leaks are present reseat vacuum tester.

6. Run the pump for a few minutes while monitoring the

vacuum gauge. If the gauge indicates a reading

between -25 and -20 in. Hg. (inches of mercury) then

it can be assumed that the pump is working correctly.

7. If the vacuum tester gauge indicates a reading below

-20 in. Hg, it can then be assumed that the pump is

not functioning correctly, and corrective action needs

to be taken.

8. To test the flapper valve, shutdown the engine. The

vacuum tester should remain attached to the pump

suction inlet port by vacuum. This indicates the pump's

flapper valve is seating properly to hold water in the

suction hose when the engine is stopped. This prevents

backflow and allows for faster priming when the engine

is restarted.

NOTICE

25 in. Hg (inches of mercury) translates into 25 feet of

lift at

sea level.

MAINTENANCE (PUMP)

CAUTION

DO NOT attempt to start the engine unless the pump

has previously been

primed with water. Severe pump

damage will occur if pump has not been primed.

This manual is related to the following products: