beautypg.com

Mvc-70e/ew— initial start-up – Multiquip MVC70E/EW User Manual

Page 19

background image

MVC-70E/EW PLATE COMPACTOR — OPERATION & PARTS MANUAL — REV. #0 (01/25/06) — PAGE 19

MVC-70E/EW— INITIAL START-UP

6. Grasp the starter grip (Figure 16) and slowly pull it out. The

resistance becomes the hardest at a certain position, corre-
sponding to the compression point. Pull the starter grip briskly
and smoothly for starting.

7. If the engine has started, slowly return the choke lever

(Figure 17) to the

“OPEN”

position. If the engine has not

started repeat steps 1 through 6.

Figure 16. Starter Grip

8. Before the pump is placed into operation, run the engine for

several minutes. Check for fuel leaks, and noises that would
associate with a lose component.

9. To begin pumping, place the throttle lever (Figure 18) in the

"

RUN"position.

Figure 17. Choke Lever (Open)

Figure 18. Throttle Lever (Run)

Stopping The Engine

Normal Shutdown

1. Move the throttle lever to the IDLE position (Figure 19) and

run the engine for three minutes at low speed.

Figure 19. Throttle Lever (Idle)

2. After the engine

cools

, turn the engine ON/OFF switch to the

OFF” position (Figure 20).

3. Place the

fuel shut-off lever

(Figure 21) in the OFF

position.

Figure 20. Engine ON/OFF Switch (OFF)

Figure 21. Fuel Valve Lever (OFF)

Emergency Shutdown

1. Move the throttle lever quickly to the

IDLE

position, and place

the engine ON/OFF switch in the

OFF

position.