General Machine Products Co., Inc.
4.5
Adjust the red screw adjuster on the air motor lubricator using a 4mm hex
wrench to allow one drip of oil per minute as viewed in the oiler site dome. Air
must be on and driving fan for this adjustment. This will be almost closed.
(When set, this will not require frequent adjustment)
4.6
The aftercooler system is now available for use.
4.7
Condensate from the filters will be collected in the plastic container. Dispose of
the contents in an environmentally acceptable way for oil contaminated waste.
The can should be emptied when approximately three quarters full.
Use 4mm hex wrench for adjusting
lubrication amount
Remove oil reservoir
by turning 1/4 turn
counter-clockwise to fill
Air motor adjustment knob