4 leveling the griddle, 5 electrical installation – Garland SHDUGR10000 INDUCTION SINGLE / DUAL COUNTERTOP GRIDDLES User Manual
Page 14

Installation
RTCSmp Induction Single and Dual Countertop Griddles
14
Part # 4532292 Rev 3 (01/14/14)
4.4 Leveling the Griddle
To help draining grease down into the grease drawer, adjust the feet to tilt the griddle with a slight angle (less
than 1 degree).
4.5 Electrical Installation
IMPORTANT
• Refer to the specifications in chapter 3 Dimensions and Technical Specifications AND the rating
plate/instruction labels on the unit. Always refer to the rating plate/instruction labels on the unit to
verify the electrical data. Rating plate/label information overrides the information listed in this manual.
• Ensure the supply voltage and the line current match the specifications given on the rating plate. A
stable mains supply must be provided.
CAUTION
Wrong voltage will damage the induction unit. Follow
strictly the specifications on the rating plate.
• The electrical connections must satisfy the national and local electrical codes.
• If ground fault current protective switches are used, they must be provided with selective activation and
designed for a minimum fault current of 30mA. Multiple generators with a mains connection must not be
connected to a single fault current protective switch.
• This induction unit is equipped with a power cable which can be connected with the necessary plug to
the socket. Ensure the plug is easily accessible for disconnecting from the power supply. Put the control
knob in the 0 (OFF) position BEFORE connecting to the electrical supply.
To setup the unit for operation:
1. Ensure the control knob is at the OFF-Position.
ON-Position
Any position where
the White Line is
not pointing at ‘0’.
OFF-Position
White Line is
pointing at ‘0’.
2. Remove all objects from the griddle plate.
3. Connect the unit to power supply.
4. Perform the Function Test. See chapter 5 Function Test.