Troubleshooting

Vacuum cleaner won’t run

Possible Causes

Remedies

Power cord not plugged in

Check electrical plug

Blown fuse/tripped breaker

Check/Replace fuse or

reset

breaker

Vacuum cleaner won’t pick up dirt

Possible Causes

Remedies

Incorrect Height Adjustment

Adjust Powerfoot to correct

height

setting

Hose not attached to suction opening

Grasp Quick Reach Handle and

firmly push Hose Wand onto the

suction

opening

Twist ‘n Snap Hose not securely attached.

Make sure Twist ‘n Snap Hose is

snapped into locked position

Crack or hole in Hose

Check Hose and replace if needed

Broken or worn Drive Belt

Replace Drive Belt, see pg. 9-10

Rotating Floor Brush bristles worn

Replace brush

Rotating Floor Brush jammed

Remove brush and clean debris from

brush

ends

Clog in vacuum

Clear clog, see pg. 11-12

Dirt Container full

Empty Dirt Container

1

1

2

2

1

1

2

2

3

3

4

4

5

5

WARNING:

To reduce the risk of injury from moving
parts and/ or electrical shock, turn Power
Switch OFF and disconnect polarized plug
from electrical outlet before performing
troubleshooting checks.

5.

6.

Suction Inlet

Air Passageway

Louvers

Hose Wand Base

Check Upper Tank and Louvers for build up or clogs.
Check to make sure Louvers are installed correctly. To
unlock the Louvers, grasp the rim and turn toward the left.
Pull straight down to remove. If the Louvers are
missing or not locked into place, check and clear the tube
in the center of the Dirt Container.

Remove the Twist ‘n Snap Hose from the vacuum by
turning to the left. Check the Suction Inlet, Hose and Hose
Wand for clogs. Remove any clogs from the hose using a
long, narrow object.

Check the Foot Hose for clogs. If needed, remove the screw
attaching the Hose Wand Base to the vacuum. Straighten
the Foot Hose and unclog with a long, narrow object.

If the clog persists, follow the instructions for Checking
the Rotating Floor Brush on page 9-10 and inspect the Air
Passageway for obstructions.

3.

4.

Clearing Clogs Continued