beautypg.com

Dickson TM320 User Manual

Tm320, Display temperature & humidity logger

background image

TM320

Phone: 1-800-757-3747 | Fax: 1-800-676-0498 | Email: [email protected] | For calls outside the US please call: 1-630-543-3747

_________________________________________________________________________________________________

Display Temperature & Humidity Logger

_________________________________________________________________________________________________

Specifications

Alarm Type: Audio/Visual on High/Low Humidity Limits; Audio/Visual on High/Low Temperature Limits
Ambient Operating RH Conditions : 0-95% RH non-condensing
Ambient Operating Temperature Conditions: -4 to 158F (-20 to 70C)
Approvals: CE
Battery Backup: Yes, with use of AC Adapter
Battery Life (Avg): 6 Months
Cable Details: USB - Male Series A plug to 5 pin Male Series B mini plug. Serial - 9 pin female D-shell to male 2.5mm
stereo plug
Cable Length: 6ft
Calibration Options: N100, N300, N400, N520
Channels: CH1: Temperature, CH2: Humidity
Data Capacity: 32,000 (16,000 per Channel)
Dimensions: 1.6 x 3 x 4in
Display Dimensions Height: 1.375
Display Dimensions Width: 2.0
Display Resolution: 0.1 from 0.0 to 999.99; 1 over 1000
Display Type: LCD
Display Update Rate: 10 Seconds (Battery Power), 1 Second (AC Power)
Download Time: 1 Minute (USB), 3 Minutes (Serial)
Download Type: USB / Serial / Flash Card
Humidity Accuracy: +/-2% RH from 0 to 60% (+/-3% RH from 60 to 95%)
Humidity Range: 0-95% RH non-condensing
Humidity Sensor Type: Monolithic IC Humidity Sensor
IP Rating: 20
Included Accessories: Four AA Batteries and Quick Start Guide. *Software is not included.
Memory Type: EEPROM, Removable Flash Storage Device
Minimum Software Version Required: 8.3
Mounting Options: Wall Mount (With Keyhole)
Network Connectivity: MP100
PC Requirements: Microsoft Windows 98 or newer, 16 MB RAM, 1 free COM (serial) port with dedicated interrupt or 1
USB root hub, CD drive, VGA monitor or better
Power Source: Four AA Batteries (User Replaceable) *AC Adapter is not included, but can be used.
Power Source Notes: AC Power is optional, but not included.
Power Status Indicator: LCD Display
Response Time: 1 Minute to 63% of Full Scale
Sample Interval: User Selectable (from 1 second to 24 hour intervals, in 1 to 10 second increments).
Software Options: A015, A025, A016, A026
Temperature Accuracy: +/-0.8F from 20 to 120F (+/-0.44C from -7 to 49C)
Temperature Range: -4 to 158F (-20 to 70C)