Internal exhausting, Electrical connection, Use and maintenance – Glen Dimplex Home Appliances Ltd DIH900 User Manual

Page 6

background image

6

Note: Depending on the location and the construction of ceiling, it may be necessary
to use a more substantial method of fixing, e.g. nuts and bolts, rather than normal
self-tapping or wood screws.
B)
Mount the connector flange F above the cooker hood ventilation kit,
using the G screws (Fig. 4).
Couple the lower mounting structure C with the cooker hood A using the 6
screws I (Fig. 4).
Connect a flexible air discharge tube (not supplied), of 120mm diameter, to the F
flange (Fig. 6)
Recirculating mode only : fix the air deflector M (fig. 6) to the upper mounting structure
B using the appropriate screw P.
C) Mount the cooker hood supporting the chimney flues and inserting
the lower mounting structure to the upper mounting structure, confirm the height and fix
the 2 structures together with the appropriate 8 screws I (fig. 5).
Recirculating mode only : connect the flexible tube previously mounted on the F
flange to the deflector M (fig. 6)
External exhaust mode : connect the discharge tube previously mounted to
the F flange to the external discharge pipe.

Internal Exhausting

Charcoal filters are used to purify the air which will be recycled into the room. The filters
cannot be washed or regenerated and must be replaced every 4 months.
The charcoal filters are supplied as an optional extra, please phone Belling Spares
department on 0

844 815 3745 and quote part number CHT28.

Saturation of the activated charcoal depends on more or less extensive use of the
hood, the type of kitchen and the regularity of cleaning the grease filter. The air is
recycled into the room through the slots in the flue E.

• Electrical Connection

Before connecting to the mains supply ensure that the voltage is as stated on the rating
plate inside the cooker hood.
Warning: This appliance is fully insulated and must not be earthed.
The appliance comes with a 2 core mains cable and should be permanently connected
to the electricity supply via a double pole switched fused spur outlet with a minimum
contact clearance of 3mm in both poles.
Installation must comply with the latest IEE regulations and must be carried out by a
competent person.
The cooker hood must be protected by a 3-amp fuse.

Use and Maintenance

If your model has mechanical controls it is advisable to switch the cooker hood on a
few minutes before cooking starts and that it be left on for about 15 minutes after
cooking is completed to exhaust all the odours.
If your model has luminous controls, switch on a few minutes before cooking starts
and activate the automatic stop timer to allow the cooker hood to continue functioning
for about 15 minutes after cooking is completed to exhaust all the odours.

On the front of the hood there are (Fig. 8):