1. Simple steps to use cooling mode
Plug in the power cord and press the “POWER” button 
Press “MODE” to chose COOLING mode. 
Press “UP” or “DOWN“ to set the desired temperature. The temperature ranges from 59F to 
86F(15C~30C) 
Press, “SPEED” to set a desired fan speed. 
The fan will run first. After few minutes, the compressor will start to run if the room temperature is higher 
then the setting temperature. The compressor will stop running when the room temperature is below the 
setting temperature. 
2. Setting the timer
(1) Turn off the unit automatically:
When the unit is running, press TIMER to set operating duration, and then the LED will flash five times. 
During this period of time, press Up or Down button to adjust setting time from 0.5 hr. to 24 hr. After 
setting, the LED will flash five times and then display the room temperature again. When the operating 
duration reaches the pre-set time, the power will turn off automatically. 
(2) Turn on the unit automatically:
When the unit is off, press TIMER to set start time, and then the LED will flash five times. During this 
period of time, press Up or Down button to adjust setting time from 0.5 hr. to 24 hr. After setting, the 
LED will flash five times and then display the temperature again. Once the pre-set time is reached, the 
power will turn on automatically.
(3) Change the setting:
When TIMER is on, you can check the remaining time by pressing the TIMER button. It will flash five 
times. Press Up or Down button to adjust the timer. The timer can be canceled if you press the TIMER 
button once again when LED is flashing. 
Attention:
If the unit is suddenly turned off during operation, the compressor will start to run three minutes after 
the power is turned back on. 
3. Setting operating mode
COOLING: When this mode is selected, the fan will run first and then the compressor will start to run
five minutes after the power is on. To set your desired temperature, press UP or DOWN button. The 
temperature ranges from 15C~30C (59F~86F). When the room temperature is lower than the setting 
temperature, the compressor will stop running until the room temperature is higher than setting 
temperature. In this case, only the fan will keep running. 
FAN: When this mode is selected, the temperature setting cannot be changed, but you can set your
desired speed. There is no need to use the air exhaust duct in this mode.
DEHUMIDIFING: When this mode is selected, it presets the fan speed and mode, and these settings
cannot be changed. Under this mode, the compressor will not run, and LED will display room 
temperature. There is no need to use the air exhaust duct. You may need to drain water with the drain 
pipe if the humidity is very high. 
4 .Setting temperature
In COOLING mode, press the “UP” button to increase the temperature setting or press the “DOWN 
“ button to lower the temperature setting. When the number is flashing, it indicates the temperature you 
are setting up. When the number is lit but not flashing, it indicates the current room temperature. 
5. Setting fan speed
In COOLING and FAN mode, press “SPEED” to adjust the fan speed. There are high, medium and low 
modes. Each fan speed corresponds to one indicator on LED control panel. Please note: when unit is in 
dehumidifier mode, the fan speed cannot be adjusted. 
 
 
 