Clarus Environmental Pipe Boot Seal User Manual
Pipe boot seal installation instructions

SECTION: C3.20.165
CL0157
0314
Supersedes
New
© Copyright 2014. All rights reserved.
Pipe Boot Seal Installation Instructions
SEE NOTE #1
CUT PIPE BOOT ABOVE
REINFORCING RING
SEE NOTE #8
LAP SEALANT
FIELD OR FACTORY SEAM
6" X 6" LAP JOINT COVER STRIP
INSTRUCTIONS:
1-PIPE BOOTS MUST BE CUT TO SIZE.
2-APPLY QuickPrime Plus TO MEMBRANE WHERE
THE PIPE BOOT WILL BE PLACED.
(SEE QuickPrime Plus DIRECTIONS)
3-REMOVE THE PROTECTIVE PAPER FROM THE
PIPE BOOT.
4-MATE THE PIPE BOOT TO THE MEMBRANE.
(DO NOT TRY TO PULL UP TO TEST SEAL).
5-ROLL THE FLANGE WITH A 2" ROLLER.
6-APPLY LAP SEALANT WHERE THE PIPE MEETS THE
PIPE BOOT.
7-TIGHTEN THE HOSE CLAMP AROUND THE PIPE
BOOT AND PIPE. (ENSURE THERE ARE NO
WRINKLES OR FOLDS UNDER THE HOSE CLAMP).
8-IF THE FLANGE OF THE PIPE BOOT OVERLAPS A
FIELD OR FACTORY SEAM APPLY LAP SEALANT CAULK
AROUND THE EDGE OF THE PIPE BOOT AND THEN
PLACE A 6" X 6" COVER STRIP OVER THE BOOT
AND SEAM.
PondGard/RubberGard MEMBRANE
LAP SEALANT
STAINLESS STEEL
HOSE CLAMP
PIPE BOOT SEAL
SEE NOTE 1
QuickPrime Plus
SEE NOTE 2
SK2483
3649 Cane Run Road • Louisville, KY 40211-1961
800-928-7867 • Fax: 502-774-3624