Wiring diagrams & parts lists, Thermometer calibration – Carter-Hoffmann PHF900 User Manual
Page 5
THERMOSTAT
SET TO –40°F
SET TO 5°F
RED
RED
BLACK
WHITE
GREEN
EVAPORATOR FANS
HANDY BOX
16/2 SJO CORD
BL
AC
K
WHI
TE
BLACK
WHITE
GREEN
GREEN
WHITE
BLACK
BL
AC
K
ON / OFF
SWITCH
BLACK
WHITE
LIGHT
16/4 SJO CORD
16/3 SJO SERVICE CORD
CAPACITOR
RELAY
CAPACITOR
COMPRESSOR
S
R
HI
LIMIT
16/3 SJO
EVAP GROUND
GROUNDING DETAIL
RECP GROUND
16-4 SERVICE CORD
SEE GROUNDING
DETAIL
(2) BLUE WIRE
NUTS
16-4 SERVICE CORD
GREEN
GREEN
WHITE
WHI
TE
BL
AC
K
BL
AC
K
GREEN
GREEN
RE
D
GR
EE
N
WHI
TE
BL
AC
K
8
EVAPOR
ATOR PAN
C
5
WIRING DIAGRAMS & PARTS LISTS
PHB450, PHB480, PHB650 & PHB975 Refrigerators
115-100v, 9 running amps, 50/60 Hz
Standard Electric
7
THERMOMETER CALIBRATION
Place an oven thermometer in the center of the cabinet. Turn heater on; turn
thermostat to maximum setting and wait approximately 45 minutes. Open the
door and check inside thermometer temperature. If recalibration is required,
pry the plastic cover off the dial body and with a small flat blade screwdriver,
insert into the pointer as shown. Carefully turn the pointer with your finger to
the correct setting. Be careful not to bend the pointer. It is very fragile.