beautypg.com

Adapting to different types of gas, Regulation of burners – Bertazzoni Z36500X User Manual

Page 9

background image

9

Models C36600X (Z36 6 00 X) [C3Y0..U4X(2 or 5)A]

Adapting to different types of gas

Burner Position Injector Gas Pressure

Max Rate

Min Rate

By-pass

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary Front

R 0,90

NG

4” 3400

996

900 264

Regulated

0,54

LP

(Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Rear L & C

1,18

NG

4”

6100

1787

1500

439

Regulated

Front

C

0,70

LP

(Propane)

11”

6100

1787

1500

439

0,36

Rapid Rear

L 1,55 NG 4”

10400

3047

2500

732

Regulated

0,92

LP

(Propane)

11”

10400

3047

2500

732

0,47

Front L Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual Burner

0,49

LP (Propane)

11”

2800

820

900

264

0,29

Front L Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

Models C36500X (Z36 5 00 X) [C3W0..U4X(2 or 5)A]

Adapting to different types of gas

Burner Position Injector Gas Pressure

Max Rate

Min Rate

By-pass

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

Diam. [mm]

Auxiliary Front

R 0,90

NG

4” 3400

996

900 264

Regulated

0,54

LP

(Propane)

11”

3400

996

900

264

0,29

Semi-Rapid

Rear L and R

1,18

NG

4”

6100

1787

1500

439

Regulated

0,70

LP

(Propane)

11”

6100

1787

1500

439

0,36

Rapid Rear

L 1,55 NG 4”

10400

3047

2500

732

Regulated

0,92

LP

(Propane)

11”

10400

3047

2500

732

0,47

Centre

Inner

0,80 NG 4”

2800

820

900

264

Regulated

Dual Burner

0,49

LP (Propane)

11”

2800

820

900

264

0,29

Centre Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

CAUTION: save the orifices removed from the appliance for future use

Regulation of burners


Work surface burner adjustment
: follow the instructions below to adjust the work surface burner minimum:
1) Light the burner and set the knob to the MINIMUM position (small flame).
2) Remove the knob of the valve that is press fit on the rod of that valve.
3) The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body
and turn the choke screw to the right or left until the burner flame is adjusted to minimum
4) Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.

WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with

liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always
operates at maximum and therefore no minimum adjustment is required.









This manual is related to the following products: