Adapting to different types of gas, Regulation of burners – Bertazzoni Z36500X User Manual
Page 9
9
Models C36600X (Z36 6 00 X) [C3Y0..U4X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure
Max Rate
Min Rate
By-pass
diam. [mm.]
Type
[i.w.c.]
[BTU/h]
[W]
[BTU/h]
[W]
diam. [mm]
Auxiliary Front
R 0,90
NG
4” 3400
996
900 264
Regulated
0,54
LP
(Propane)
11”
3400
996
900
264
0,29
Semi-Rapid
Rear L & C
1,18
NG
4”
6100
1787
1500
439
Regulated
Front
C
0,70
LP
(Propane)
11”
6100
1787
1500
439
0,36
Rapid Rear
L 1,55 NG 4”
10400
3047
2500
732
Regulated
0,92
LP
(Propane)
11”
10400
3047
2500
732
0,47
Front L Inner
0,80
NG
4”
2800
820
900
264
Regulated
Dual Burner
0,49
LP (Propane)
11”
2800
820
900
264
0,29
Front L Outer
N°2 x 1,15
NG
4”
12000
3516
4500
1318
Regulated
N°2 x 0,70
LP (Propane)
11”
12000
3516
4500
1318
0,65
Models C36500X (Z36 5 00 X) [C3W0..U4X(2 or 5)A]
Adapting to different types of gas
Burner Position Injector Gas Pressure
Max Rate
Min Rate
By-pass
diam. [mm.]
Type
[i.w.c.]
[BTU/h]
[W]
[BTU/h]
[W]
Diam. [mm]
Auxiliary Front
R 0,90
NG
4” 3400
996
900 264
Regulated
0,54
LP
(Propane)
11”
3400
996
900
264
0,29
Semi-Rapid
Rear L and R
1,18
NG
4”
6100
1787
1500
439
Regulated
0,70
LP
(Propane)
11”
6100
1787
1500
439
0,36
Rapid Rear
L 1,55 NG 4”
10400
3047
2500
732
Regulated
0,92
LP
(Propane)
11”
10400
3047
2500
732
0,47
Centre
Inner
0,80 NG 4”
2800
820
900
264
Regulated
Dual Burner
0,49
LP (Propane)
11”
2800
820
900
264
0,29
Centre Outer
N°2 x 1,15
NG
4”
12000
3516
4500
1318
Regulated
N°2 x 0,70
LP (Propane)
11”
12000
3516
4500
1318
0,65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:
1) Light the burner and set the knob to the MINIMUM position (small flame).
2) Remove the knob of the valve that is press fit on the rod of that valve.
3) The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body
and turn the choke screw to the right or left until the burner flame is adjusted to minimum
4) Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.
WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with
liquid gas the screw must be locked at the end in a clockwise direction. The grill burner always
operates at maximum and therefore no minimum adjustment is required.