Features

• Isolates Start and House circuits, and combines both battery banks for

emergency starting
Tin-plated copper studs:

• 3/8"-16 (M10) provide maximum conductivity and corrosion resistance

• One-piece to reduce risk of overheating

• 7/8" (22.22mm) length to accept multiple cable terminals

Case design:

• Allows surface mounting, front or rear panel mounting

• Accepts up to 4/0 AWG (120 mm²) battery cables

• Removable knob for security and service lockout

• Removable isolator covers protect rear contacts

Specifications

Cranking Rating: 10 sec.

1,000 Amperes DC

Cranking Rating: 1 min.

650 Amperes DC

Intermittent Rating: 5 min. (UL 1107) 450 Amperes DC

Continuous Rating:

300 Amperes DC

Terminal Stud, Tin-Plated Copper

3/8"-16 (M10)

Torque

120 in-lb (13.56 N·m)

Cable Size to Meet Ratings*

4/0 AWG (120 mm²)

Maximum Voltage Rating

32 Volts DC

Ignition Protected

marked

Agency Specifications

• Meets all American Boat and Yacht Council (ABYC) requirements for

battery switches

• UL Listed - UL 1107 for electric power switches

• Meets UL 1500 and SAE J1171 external ignition protection requirements

Guarantee

Any Blue Sea Systems product with which a customer is not satisfied may be

returned for a refund or replacement at any time.

For information about Blue Sea Systems Engine Starting Standard, go to

www.bluesea.com.

* Reducing cable sizes will reduce current ratings

Caution

• Disconnect positive battery terminal before installing.

• Débranchez la cosse positive de la batterie avant de l’installer.

• Desconecte el terminal positivo de la batería antes de la instalación.

• Prima di eseguire l’installazione, disconnettere il terminale positivo della batteria.

• Consult marine electrical professional for proper wiring application.

• Consultez un professionnel de l’électricité marine pour installer le câblage correctement.

• Consulte a un electricista marino profesional para la aplicación de alambrado apropiada.

• Per assicurarsi che i cavi siano correttamente collegati, rivolgersi ad un elettricista specializzato in motori marini.

Installation

• Refer to the latest edition of NFPA 302 and/or ABYC E11 Standard for installation information.

• Attach one 4/0 AWG cable per terminal to meet ratings.

• Raccordez un câble 120mm² par cosse pour respecter les spécifications.

• Sujete un cable 120mm² por terminal de acuerdo a la clasificación.

• Attaccare un cavo 120mm² per conformarsi alle tarature.

• Battery cable terminals must be attached under nut and lock washer. Torque 120 in-lb (13.56 N·m).

• Les cosses des câbles de batterie doivent être fixées sous la rondelle de sûreté et l’écrou – couple de serrage de 13,56 N·m (120 lb-po).

• Los terminales de los cables de batería deberán ser sujetados debajo de la tuerca y la arandela. Apriételos a una torsión de 13,56 N·m (120 lbs-pul).

• I terminali del cavo della batteria vanno attaccati con un dado e una rondella elastica: coppia di 13,56 N·m (120 lbs-in).

Operation

• Turn all appliances off before turning the battery switch to OFF.

• Éteignez tous les appareils électriques avant de mettre l’interrupteur de batterie sur ARRÊT.

• Apague todos los artefactos antes de girar el interruptor de batería a APAGADO (OFF).

• Spegnere tutte le apparecchiature prima di muovere l’interruttore della batteria su OFF (spento).

• Do not switch to OFF while engine is running.

• Ne le mettez pas sur ARRÊT alors que le moteur tourne.

• No coloque el interruptor en APAGADO (OFF) mientras que el motor esté funcionando.

• Non muovere l’interruttore su OFF (spento) quando il motore è in moto.

Switch Set to "ON"

Switch Set to

"COMBINE BATTERIES"