Ventless Hood System

Maintenance

20

Maintenance

Electrocution could occur if this unit is hosed down with water. This unit is NOT
designed for hose wash-down cleaning! Refer to scheduled maintenance below
for proper hood cleaning.

Electrocution could occur if power is not removed from this unit before servicing.
Remove power at disconnect or circuit breaker BEFORE servicing hood.

Scheduled Maintenance

Use the following table to help manage scheduled maintenance activities.

FREQUENCY PERFORMED

BY

PART

ACTIVITY

Daily

User

Entire Hood

Wipe unit down with a soft rag and mild
cleaning agent.

User Condensation

trough

Check condensation trough. Empty if
necessary.

User

Grease Baffle

Clean grease baffle. If necessary, refer
to the procedure in this manual for
cleaning the baffle.

Weekly

User Particle/Odor

Filter

Inspect particle/odor filter. In low to
medium volume applications, the filter
may need replacement prior to the
indicating light turning on. This
condition will be evident by a strong
odor coming from the face of the filter.
If necessary, refer to the procedure in
this manual for replacing the filter.

Monthly

User

Door and Filter
Interlock

Check door and filter interlock
operation. The unit should not operate
with the front door open or either the
grease baffle or particle/odor filter
removed. Clean area between grease
baffle and particle/odor filter.

Injury from rotating fan blades could occur if power is not removed from this unit
before cleaning the blower section. Remove power at disconnect or circuit breaker
BEFORE cleaning the blower section.

3 Months

User

Blower Section

Clean the blower section.

6 Months

Authorized Service
agent

Fire Extinguishing
System

Have the fire extinguishing system
inspected.