Emplacement de la génératrice, Features and controls – Briggs & Stratton PRO4000 User Manual

Page 10

background image

10

BRIGGSandSTRATTON.COM

Features and Controls

Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.

A

E

G

H

P

W

M

F

N

A - Fuel Tank — Capacity of four and a half (4.5) U.S.

gallons.

B - Oil Fill Cap /Dipstick — Check and add engine oil here.

C - Fuel Valve — Used to turn fuel supply on and off to

engine.

D - Oil Drain Plug — Drain engine oil here.

E - Spark Arrester Muffler — Exhaust muffler lowers engine

noise and is equipped with a spark arrester screen.

F - Rocker Switch — Set this switch to run (I) before using

recoil starter. Set switch to stop (O) to stop engine.

G - Choke Lever — Used when starting a cold engine.

H - Engine Identification — Provides model, type and code

of engine. Please have these readily available if calling for
assistance.

J - Air Cleaner — Protects engine by filtering dust and

debris out of intake air.

K - Recoil Starter — Used to start the engine.

L - Data Tag – Provides model, revision and serial number

of generator. Please have these readily available if calling
for assistance.

M - Grounding Fastener — If required, please consult a

qualified electrician, electrical inspector, or local agency
having jurisdiction.

N - Idle Control Switch — Use this switch to turn the idle

control feature on and off.

P - 12 Volt DC Receptacle — Use this receptacle with

battery charge cables to charge a 12 Volt battery.

R - 120 Volt AC, 20 Amp Duplex Receptacle — May be

used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.

S - 120 Volt AC, 30 Amp Locking Receptacle — May be

used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.

T - 120/240 Volt AC, 20 Amp Locking Receptacle — May

be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 20 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.

V - GFCI Circuit Breaker — A GFCI circuit breaker is

provided to protect against electrical ground fault and
protect the generator against electrical overload.

W - Hour Meter — Displays and records how many hours

your generator has run (up to 9,999.9).

J

K

L

D

R

S

T

V

C

B