Lighting instructions – Bakers Pride XOB-848SU Manual User Manual
Page 4
Figure “A”
4
kPa).
8. The appliance must be isolated from the gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less then ½ psi (3.45 kPa).
9. This appliance must be installed under a ventilation hood.
10. Do not obstruct the flow of combustion and ventilation air.
11. The area around this and any other gas appliance must always be kept free and clear from
combustibles.
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
B. UNPACKING INSTRUCTIONS:
Carefully unpack the open burner range and inspect immediately for shipping damages. Your open
burner range was shipped in a carton designed to give maximum protection in normal handling. It
was thoroughly inspected before leaving the factory and the carrier accepted and signed for it. File
any claims for shipping damage or irregularities with the carrier.
C. GAS CONNECTIONS
STANDING
PILOT
A separate gas shut off valve (supplied with
unit) must be installed in the gas line ahead of
the unit, as required by codes (see Fig. A).
Gas supply line must be ¾” or larger. If flexible
semi rigid connections are used, the inside
diameter must be the equivalent of ¾” iron
pipe or larger. All connections of the flexible
and semi rigid type must be AGA listed and
comply with applicable ANSI standards. Make
sure gas piping is clean and free of dirt, piping
compound and obstruction. To insure
maximum operating efficiency, this appliance
must be connected with a Gas Supply Line of
solid pipe or with a Commercial Type Flexible
Connector with I.D. (inside diameter) equal or
larger than the gas pipe inlet on this
appliance.
CAUTION: BEFORE LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS. USE
SOAP AND WATER SOLUTION. DO NOT USE OPEN FLAME.
If the gas connections are leak-free, the unit is ready to use. Follow the lighting instructions.
PRESSURE REGULATOR
MAIN SHUT-OFF VALVE
2. LIGHTING INSTRUCTIONS
A. LIGHTING INSTRUCTIONS
1. Turn off all gas valves and main Shut-off valve and wait 5 minutes.
2. Turn the main gas valve to ON position and light standing pilots adjacent to each main
burner. (FIG. A & B)
3. Repeat the above step for all standing pilots. There should be slight yellow tip on the pilot flame.
Make sure all the pilots are lit.
4. Turn the main burner valve to the ON position.
5. To relight follow steps 1-4.
B. SHUTDOWN INSTRUCTIONS
For complete shut down turn all the main burner valves and main gas valve to OFF position.
Pilot should be approximately ½”- ¾” in height. Adjust as required
by turning the pilot adjusting screw located on the manifold pipe.