Options – APG FL Series datasheet User Manual
Page 3
![background image](/manuals/554703/3/background.png)
Options
Part Number: FLR - _____ _____ - _____ - _____ - _____ - _____ - _____ - _____ - _____
A B C D E F G H I
APG
Automation
Products
Group,
Inc. www.apgsensors.com
tel. 888.525.7300
3
A. Mounting Type
□
0
Flat face flange
□
1
Raised face flange
□
2
Slide adapter
□
3
3A Sanitary ferrule
□
4
Plug mounted from outside of tank
□
5
Plug mounted from inside of tank
B. Mounting Option and Size
□
A
Ansi flange 150# (size=2, 2.5, 3, 4)
□
J
JIS flange 10 kg/cm2 (size=2)
□
D
DIN flange 10 kg cm2 (size=50)
□
SF 3A Sanitary ferrule (size=2, 2.5, 3, 4)
□
T
NPT plug (size=1.5, 2, 2.5, 3, 4)
(inside size=0.25, 0.5, 0.75, 1, 1.5, 2)
□
G
PF plug (size=2, 2.5, 3)
(inside size=0.75, 1, 1.5, 2)
□
R
RT plug (size=2, 2.5, 3)
(inside size=0.75, 1, 1.5, 2)
□
X
Other
C. Material
□
S
304 SS
□
S6 316L SS
D. Housing
□
H1 NEMA 4 & 7, IP65 (1/2 in. canle entry)
□
H3 NEMA 4 & 7, IP65 (3/4 in. cable entry)
□
W
No housing, mounting option with 3/4 NPT plug
and 12 in. lead wires
E. Reed Switch
□
A
50 VA
□
C
180 VA
F. Number of Switch Points
□
1-7 Select the number of switch points required
G. Number of Floats
□
1-7 Select the number of floats required
H. Float Type
□
K
Buna (for A reed switch only)
□
AA 316L SS (2.06 in. diameter)
□
BB 316L SS (1.63 in. diameter)
I. Probe Length (in./mm)
□
L_ in./mm
Switch Point Location(s)
(Measured from process connection)
□
1
____ in./mm (designate NO or NC position
□
2
____ in./mm (designate NO or NC position
□
3
____ in./mm (designate NO or NC position
□
4
____ in./mm (designate NO or NC position
□
5
____ in./mm (designate NO or NC position
□
6
____ in./mm (designate NO or NC position
□
7
____ in./mm (designate NO or NC position