Options
PT- ____ - C - _____ - _____ - _____ - _____ - _____ - _____ - _____ - _____ - _____ - _____ - _____
A
B C
D E F G H I J K L
A. Operation
□
L1 4-20 mA
□
L11 1-6 VDC
□
L3 0-5 VDC
□
L12 1-5 VDC
□
L10 0-10 VDC
B. Common Pressure Ranges
□
5
□
50
□
200
□
1000
□
5000
□
15
□
60
□
300
□
2000
□
10000
□
30
□
100
□
500
□
3000
*Other ranges available
C. Unit of Measure
□
PSI▲
□
kPa
□
inHg
□
bar
□
inH
2
O
□
kgcm
2
□
mbar
□
mmHg
□
fsw
D. Pressure Type
□
G Gauge
□
A
Absolute
□
CG Compound Gauge
□
S
Sealed
□
V
Vac
E. Electrical Connection
Mating connector sold separately
□
E1 6-pin circular
□
E5▲ Pigtail with cable
□
E3 4-pin bayonet
□
E17 6-pin bayonet
□
E4 4-pin M12 Micro connector
F. Elelectircal Cable Length
Use with E1, E3, E4, E17 connections
□
W0 0 ft
Use with E5 pigtail connection
□
W1 2 ft (0.6 m)
□
W4 25 ft (7.6 m)
□
W2 5 ft (1.5 m)
□
W5 50 ft (15.2 m)
□
W3 10 ft (3 m)
Automation Products Group, Inc.
www.apgsensors.com
tel. 888.525.7300
3
G. Process Connection
□
P0▲ 1/4-18 NPTM
□
P16 PT 1/4 (BSPP) male
□
P2 1 1/2 sanitary
□
P22 G3/8 (3/8 BSPP) male
□
P4 7/16-SAE male flush mount
□
P5 1/4-18 NPTF
□
P23 G1/2 (1/2 BSPP) male
□
P7 7/16-20 SAE male
□
P26 7/16-20 UNF male w/
cone
□
P14 1/8-27 NPTM
□
P30 High Pressure Sno Trik
(M-250C, Autoclave male)
H. Accuracy
□
N0▲ ±0.25%
□
N1 ±0.25% with NIST certification
□
N2 ±0.1% with NIST certification
□
N3 ±1% or better
□
N4 ±1% or better with NIST certification
□
N12 ±0.5% (standard on ranges greater than 5000
psi and voltage output only)
□
N13 ±0.5% with NIST certification
I. Materials
□
M0 15-5 SS
□
M1▲ 316L SS or 316L/Hastelloy
□
M5 Hastelloy (minimum quantities required)
J. Vibration
□
V0▲ Standard
□
V1 High (not available with K0)
K. Can Assembly
□
K0▲ Knurl
□
K1 Tamper resistant with Loc-Tite
□
K2 Tamper resistant with weld
□
K3 Weld can to fitting and connector
L. Temperature
□
S0▲ Standard: 0º - 130ºF (-17º - 54ºC)
□
S1 Extended: -40º - 180ºF (-40º - 82ºC)
Note:
▲
Indicates this option is standard.