IRU-2420 Specifications
Performance
• Operating Range
1 - 25 ft. (0.3 - 7.6 m)
• Beam Pattern: 9º off axis
• Internal Temperature Compensation
• Frequency: 69 kHz
• Accuracy: ±0.25% of detected range
• Resolution: 0.1 in. (2.5 mm)
• Response Time: Programmable (20 ms minimum)
Connectivity
Output:
• 4-20 mA
600 ohms @ 24 VDC
150 ohms @ 12 VDC
• 4-20 mA with (2) NPN outputs
Environmental
• Ratings: IP65
• Operating Temp: -40º - 140ºF (-40º - 60ºC)
Electrical
• Total Current Draw: 75 mA @ 24 VDC
• Supply Voltage: 12-28 VDC
• Wiring Connection: 4 or 5 conductor shielded cable
Programming
• Interface with RST-3001/3002 Programmer
(purchase separately - powered by USB)
-The RST-3001 is 32 bit only
-The RST-3002 is 32 and 64 bit compatible
• User selected units of measure
Physical
• PVDF (Kynar®) transducer housing
• PC/PET upper housing
• Transducer Type: Ceramic, PVDF faced
Certification
• Class 1, Div. 2, Groups A, B, C, D
• IP65
Automation Products Group, Inc.
www.apgsensors.com
tel. 888.525.7300
2
1.49”
37.84 mm
3.05”
77.47 mm
5.10”
129.54 mm
7.23”
183.64 mm
1.99”
50.54 mm
Liquid Tight
Non-Metallic
Spiral Strain Relief
3/4” NPT
Threads
2” NPT
Threads