Specifications, Specifications 5 – Behringer EUROPOWER Amplifier with ATR EP2000 User Manual
Page 12
ENGLISH
EUROPOWER EP2000/EP4000 User Manual
12
Specifications
5.
Output Power
RMS @ 1% THD (sine wave), both channels driven
EP2000
8 Ω per channel
350 W
4 Ω per channel
500 W
2 Ω per channel
650 W
EP4000
8 Ω per channel
550 W
4 Ω per channel
950 W
2 Ω per channel
1250 W
RMS @ 1% THD (sine wave), bridged mode
EP2000
8 Ω
1000 W
4 Ω
1300 W
EP4000
8 Ω
1750 W
4 Ω
2400 W
Peak Power, both channels driven
EP2000
8 Ω per channel
400 W
4 Ω per channel
750 W
2 Ω per channel
1000 W
EP4000
8 Ω per channel
750 W
4 Ω per channel
1400 W
2 Ω per channel
2000 W
Peak Power, bridged mode
EP2000
8 Ω
1500 W
4 Ω
2000 W
EP4000
8 Ω
2800 W
4 Ω
4000 W
Distortion
EP2000
< 0.01%
EP4000
< 0.02%
Frequency Response
at 10 dB below rated output power 20 Hz - 20 kHz, +0/-1dB
at -3 dB points
5 Hz - 50 kHz
Damping Factor
EP2000/EP4000
> 300 @ 8 Ω
Noise
unweighted, 20 Hz to 20 kHz
-100 dB
Voltage gain
EP2000
40x (32 dB)
EP4000
50x (34 dB)
Input sensitivity
V RMS (@ 8 Ω)
EP2000 1.15 V (+3.4 dBu)
EP4000 1.23 V (+4.0 dBu)
Input impedance
EP2000/EP4000
10 k Ω unbalanced, 20 k Ω balanced
Controls
Front
Power switch,
gain control (channels 1 and 2)
Rear
DIP switches (10x)
Indicators
POWER
green LED
CLIP
red LED, 1 per channel
SIGNAL
yellow LED, 1 per channel
Connectors
Inputs
Balanced XLR and ¼" TRS connectors
Outputs
Touch-Proof binding posts and
professional speaker connectors
Cooling
EP2000/EP4000
Continuously variable speed fan,
back-to-front air flow
Amplifier protection
EP2000/EP4000
Full short circuit, open circuit, thermal
and HF protection Stable into reactive or
mismatched loads
Load protection
EP2000/EP4000
Turn-on/off muting, AC coupling
Output circuit type
EP2000
Class AB complementary linear output
EP4000
Class H complementary linear output
Power supply
Mains voltage/Breaker
100 - 120 V~, 50/60 Hz
15 A
220 - 230 V~, 50/60 Hz
8 A
Power consumption
EP2000
1600 W
EP4000
2600W
Mains connector
Standard IEC receptacle