beautypg.com

Number of devices, Pl-anet, Mounting into furniture – Allen&Heath PL-10 User Manual

Page 2: Grounding, Pl-anet connections, End of chain termination, Testing the wiring, Powering up the pl system, Configuring the controls, Further information

background image

2

PL-10 User Guide AP5708 issue 2

Number of devices

The maximum number of

PL devices that can be connected depends on their
type, cable lengths and PL-Anet Bus Speed. Up to 18x
PL-10 devices may be connected in an iDR system
with the half speed PL-A-net Bus setting. Fewer
devices may be connected if long distances, full bus
speed or other PL types are involved. Long distances
up to 300m (1000’), and star point connection are
possible if the optional PL-9 PL-Anet hub is used.
Before starting, refer to the PL Combinations Calculator
spreadsheet available as a download from the Allen &
Heath web site.

iDR

PL-9 HUB

TERMINATION

TERMINATION

TERMINATION

PL-Anet

is the proprietary Allen & Heath system

for daisy chaining remote controllers. It is an RS485
serial connection that uses CAT5 STP cable to
communicate between devices over long distances. It
requires a terminator at the last unit in the chain. PL-
Anet only works with Allen & Heath PL devices. The
connection includes +20V DC to power the connected
devices. The iDR-8 port is shown here.

Mounting into furniture

Cutting template

details are shown here for mounting the PL-10 into a
plinth or other furniture. Secure the unit in place using
4x fixing screws up to 3.5mm diameter.

92

156.5

CUTOUT

212 x 147 mm

Allows 1mm clearance each side

170.5

225

DIA 4

37

51

Grounding

The exposed metal panels are

grounded through the PL-Anet cable shield. There are
no dangerous voltages inside.

PL-Anet connections

Underside RJ45 ports

are provided for connecting to PL-Anet. These are
recessed so that the cables can be hidden from view.
The IN port connects to the previous unit in the chain.
The OUT port connects to the next unit, or end of chain
termination. Use flame retardent CAT5 STP (shielded
twisted pair) RJ45 cables.

IN

OUT

TO AVOID DAMAGE ONLY CONNECT

CAUTION 20V DC

COMPATIBLE REMOTE CONTROL

EQUIPMENT TO THE PL-Anet PORT.

PL-Anet

SERIAL NUMBER

Made in the UK by ALLEN&HEATH LIMITED

previous

next

TERMINATOR

PLUG

AN

57

09

PL-10

End of chain termination

As with any

RS485 system, the last PL device needs to have a
terminating resistor fitted to its output port. The PL-10
is shipped with an RJ45 terminator plug with this
resistor built in. Plug the terminator into the last unit in
the PL-Anet chain. If the PL-10 is the only unit
connected make sure the terminator is plugged into its
output port.

Testing the wiring

Before powering up

the system make sure all the wiring is inspected and
continuity tested. This is important as wiring errors
may result in damage to the equipment.

Powering up the PL system

Ensure that

the iDR PL-Anet port is active. Its green ‘active’ LED
should be lit. If not, use the iDR System Manager
software Communications Option menu to activate the
port. Plug in the PL-Anet cable. The screen will display
icons on the right hand toolbar for each PL device it
recognises. Check that the PL-10 front panel status
LED displays green. If red or yellow is displayed then
check for wiring or equipment faults.

STATUS

Configuring the controls

The rotary

encoders, switches and LED indicators are configured
using the iDR System Manager software. Note that the
LEDs are 3-colour and can display green, red, yellow or
off. Refer to the Help file that comes with the software.

LED / SOFTKEYS

LED / SOFTKEYS

LED

LEDs

ENCODERS

Further information

Visit the Allen & Heath

web site for information on the full PL product range
www.allen-heath.com. If further assistance is required
please contact Allen & Heath technical support.

DIGITAL EXPANDER

PL-ANET

DR-LINK

AUDIO OUT

AUDIO IN

TO AVOID DAMAGE ONLY CONNECT

CAUTION 20V DC

COMPATIBLE REMOTE CONTROL

EQUIPMENT TO THE PL-ANET PORT.