SECTION 2 - PROCEDURES
2-8
– JLG Lift –
3120743
 - Drive inhibited.
 - Flashes in neutral until fault is cleared. 
6.  5 FLASHES - Motor Neither Low Nor High. (Open
Circuit)
 - Direction contactors (or line contactor) did not
close.
 - Point ‘A’ not within 6V of B + ve after 500mS.
 - Drive inhibited.
 - Flashes until fault is cleared, when contactor
closes. 
NOTE: If recycling to neutral does not clear the fault, then
the fail-safe is due to an S/C contactor coil and the
key switch must be recycled (and coil replaced). 
Figure 2-1. Sevcon Controller Troubleshooting Flow
Charts. (Sheet 2 of 4).
7.  6 FLASHES - Drive Hand Controller Fault.
 - 3.5-0V Input: Voltage <2.5V on power up.
 - Voltage >4.5V in drive.