Top Panel Trim Installation
Installation of 1/2" x 5" Trim on Top Panels
•
Trim is used to finish off all Walk-In Cooler and Freezers other than Drop-Off units and is left to the installer, as
not all field conditions are identical. Trim is packed with each shipment (as required) from W. A. Brown.
•
Install corner trim pieces first. Use four #6 self tapping screws supplied (See Figure 13-1). Install trim metal
between corners. Overlap all joints by 1/2". Use one screw every 2' (See Figure 13-2). Caulk bottom of trim as
needed. An inverted corner will not use corner trim pieces. Full length pieces are to be butted together in the
corner (See Figure 13-3)
Figure #13-1
Figure #13-2
Figure #13-3
Drop-Off Walk-In Coolers and Freezers
Prior to the arrival of your Drop-Off Walk-In, you are responsible for assuring that the concrete slab is the appro-
priate size, thickness and level. Remember that the Drop-Off unit comes on metal runners which will affect the
height of the floor.
Upon arrival, visually inspect the Walk-In for dents, scratches and other issues.
Unload the Walk-In and position properly. Finish door and threshold trimming.
Final positioning of the Drop-Off unit is the responsibility of the end user or general contractor.
Make final electrical connections in accordance to prevailing codes and start the cool down process.
Warning!
The electricity should not be turned on any door with a heater
until the refrigeration system has been activated, as a failed heater wire may
result. Do not operate Light with globe unless unit is cooled down. Maximum
bulb size is 100 watts